A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

pH Nanosensor Using Electronic Spins in Diamond. | LitMetric

Nanoscale measurements provide insight into the nano world. For instance, nanometric spatiotemporal distribution of intracellular pH is regulated by and regulates a variety of biological processes. However, there is no general method to fabricate nanoscale pH sensors. Here, we, to endow pH-sensing functions, tailor the surface properties of a fluorescent nanodiamond (FND) containing nitrogen-vacancy centers (NV centers) by coating the FND with an ionic chemical layer. The longitudinal relaxation time of the electron spins in the NV centers inside a nanodiamond modified by carboxyl groups on the particle surface was found to depend on ambient pH between pH 3 and pH 7, but not between pH 7 and pH 11. Therefore, a single particle of the carboxylated nanodiamond works as a nanometer-sized pH meter within a microscopic image and directly measures the nanometric local pH environment. Moreover, the pH dependence of an FND was changed by coating it with a polycysteine layer, which contains a multitude of thiol groups with higher p. The polycysteine-coated nanodiamond obtained a pH dependence between pH 7 and pH 11. The pH dependence of the FND was also observed in heavy water (DO) buffers. This indicates that the pH dependence is not caused by magnetic noise induced by H nuclear spin fluctuations, but by electric noise induced by ion exchanges. our method, the sensitive pH range of the nanodiamond pH sensor can potentially be controlled by changing the ionic layer appropriately according to the target biological phenomena.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsnano.9b05342DOI Listing

Publication Analysis

Top Keywords

dependence fnd
8
noise induced
8
nanodiamond
5
nanosensor electronic
4
electronic spins
4
spins diamond
4
diamond nanoscale
4
nanoscale measurements
4
measurements provide
4
provide insight
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!