Objectives of the study were the prevalence and clinical consequences of balloon rupture with compliant balloons in balloon aortic valvuloplasty (BAV). Compliant low-profile balloons have been developed to reduce access site complications. Made by thinner materials, these balloons are more prone to rupture. This is a single-center retrospective analysis (2016-2018) of patients undergoing BAV with compliant balloons. Baseline echocardiography and computed tomography (CT) were analyzed. Best cutoff point for calcium score was assessed. Long-term mortality was analyzed with Kaplan-Maier. In vitro test was performed. Rupture occurred in 30/90 (33%) of BAVs independent of risk factors, surgical risk and frailty scores. Patients experiencing rupture had increased mean gradient [53.5 (44-64) vs 44 (35-49) mmHg, p < 0.05] and reduced aortic valve area [0.61 (0.46-0.76) vs 0.76 (0.64-0.83) mm, p < 0.05]. Valve calcium score on CT > 2686 AU was more frequent in the rupture group (41% vs 10%, p < 0.05) and more patients in the third tertile of calcium score experienced rupture (75% vs 23% vs 41% for second and first tertile, p < 0.05). Median gradient reduction from baseline was similar among groups [30 (20-50) vs 30 (17-39) mmHg]. No patient with rupture had any complication. One-month and long-term mortality were similar (rupture 0% vs 3.5% no rupture from 1 month). In vitro test required more volume and strength to rupture the balloon than used in BAV. Balloon rupture is frequent in BAV using compliant balloons, occurs with more severe aortic stenosis, does not affect BAV efficacy and does not impair outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12928-019-00623-8 | DOI Listing |
Am J Obstet Gynecol MFM
January 2025
Division of Maternal Fetal Medicine, Brigham and Women's Hospital.
Background: As induction of labor increases in the United States, safe, effective outpatient cervical ripening has been explored as a method to decrease the inpatient time burden. The most effective method of outpatient mechanical cervical ripening remains unclear.
Objective: To evaluate if Dilapan-S is non-inferior to cervical balloon for outpatient cervical ripening (CR) based on change in Bishop score.
J Invasive Cardiol
January 2025
Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania.
Objectives: The Wolverine cutting balloon (CB) (Boston Scientific) is a specialized balloon catheter with microsurgical blades that is used for balloon-resistant lesions. The Manufacturer and User Facility Device Experience (MAUDE) database serves as a repository for reports of medical device complications. The aim of this study was to analyze complications associated with CB use during percutaneous coronary intervention in real-world contemporary practice.
View Article and Find Full Text PDFCardiovasc Interv Ther
January 2025
Department of Cardiology, Tokyo Medical University Hospital, 6-7-1 Nishi-Shinjuku, Shinjuku-Ku, Tokyo, 160-0023, Japan.
Eur Heart J Case Rep
January 2025
Institute of Cardiovascular Sciences, University of Birmingham, Birmingham B15 2TT, UK.
Background: Valve sparing aortic root replacement (VSARR) is a treatment for aortic root dilatation and aortic regurgitation (AR), which preserves the aortic valve. However, AR may recur, and redo surgery often carries high risk. Transcatheter aortic valve replacement (TAVR) can be performed but there is a paucity of literature to guide procedural planning.
View Article and Find Full Text PDFJ Intensive Care Med
January 2025
The George Washington University School of Medicine and Health Sciences, Washington, DC, USA.
Introduction: Endotracheal tube (ETT) malpositioning can result in a myriad of complications. Daily chest radiographs (CXR) is the gold standard in monitoring these complications. Point-of-care transtracheal ultrasound (TTUS) is an emerging imaging modality for ETT positioning.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!