Background: Most manufacturer manuals do not verify the use of dual energy X-ray absorptiometry for body composition analysis in subjects with a metal implant. This study aimed to quantify the effects of a spinal implant on body composition, and to determine whether unadjusted lean mass estimates are valid for patients with a spinal implant.
Methods: A total of 30 healthy subjects were recruited. Three consecutive scans were performed for each participant, one with and two without extraneous spinal implant, without repositioning between scans. Lean, fat and bone estimates in the total body, trunk and limb were measured.
Results: Precision errors for all total and regional body compositions were within the recommended ranges. Bone masses in the trunk and total body were significantly increased with spinal implant, and the increases exceeded the least significant change. For total and regional lean and fat estimates, the measurements between subjects with and without metal implants were in substantial to almost perfect agreement and the differences were not significant and did not exceed the least significant change.
Conclusions: Spinal metal artifacts significantly increased the total body and trunk bone mass but the differences in lean- and fat-related estimates at total and regional body levels and all estimates in the extremity remained within the clinical acceptable range. Thus, a spinal implant may not compromise screening of patients for fat and lean masses using dual energy X-ray absorptiometry. Application of image reconstruction or a filtering algorithm may help reduce the effect of metallic artifacts and further study is needed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752773 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0222758 | PLOS |
Nat Commun
January 2025
State Key Laboratory of Cardiology and Medical Innovation Center, Shanghai East Hospital, Frontier Science Center for Stem Cell Research, Bioinformatics Department, School of Life Sciences and Technology, Tongji University, Shanghai, China.
Vet Res Commun
January 2025
Department of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Chronic instability at the lumbosacral junction, particularly between the L7 vertebra and the sacral bone, presents significant challenges in veterinary orthopedics, especially for large breed dogs. This condition frequently results in severe pain, neurological deficits, and mobility impairments, prompting the development of various surgical techniques aimed at effectively stabilizing the affected area. A critical evaluation of the literature on surgical stabilization of the lumbosacral spine in dogs reveals the clinical applications, outcomes, and future directions in veterinary spinal surgery.
View Article and Find Full Text PDFEur Spine J
January 2025
In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.
Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.
Clin Infect Dis
January 2025
Department of Spinal Surgery, Shihezi General Hospital of the eighth Division, Shihezi, 832002, China.
BMC Musculoskelet Disord
January 2025
Spine Center and Department of Orthopedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, 1342, Dongil-Ro, Seoul, Nowon-Gu, 01757, Republic of Korea.
Background: The safety of endovascular treatment, such as thoracic endovascular aortic repair (TEVAR), for a descending thoracic aortic aneurysm has been well-established, with a reported low postoperative mortality rate but higher incidences of long-term complications such as endo-leakage, device failure, and aneurysm-related death. Based on this, we report the first case of massive thoracic vertebral body erosion due to a perianeurysmal outpouching lesion after TEVAR.
Case Presentation: A 77-year-old female with a history of TEVAR due to descending thoracic aortic arch aneurysm 4 years ago was referred from the cardiovascular clinic to the spine center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!