Image quality metrics (IQMs) such as root mean square error (RMSE) and structural similarity index (SSIM) are commonly used in the evaluation and optimization of accelerated magnetic resonance imaging (MRI) acquisition and reconstruction strategies. However, it is unknown how well these indices relate to a radiologist's perception of diagnostic image quality. In this study, we compare the image quality scores of five radiologists with the RMSE, SSIM, and other potentially useful IQMs: peak signal to noise ratio (PSNR) multi-scale SSIM (MSSSIM), information-weighted SSIM (IWSSIM), gradient magnitude similarity deviation (GMSD), feature similarity index (FSIM), high dynamic range visible difference predictor (HDRVDP), noise quality metric (NQM), and visual information fidelity (VIF). The comparison uses a database of MR images of the brain and abdomen that have been retrospectively degraded by noise, blurring, undersampling, motion, and wavelet compression for a total of 414 degraded images. A total of 1017 subjective scores were assigned by five radiologists. IQM performance was measured via the Spearman rank order correlation coefficient (SROCC) and statistically significant differences in the residuals of the IQM scores and radiologists' scores were tested. When considering SROCC calculated from combining scores from all radiologists across all image types, RMSE and SSIM had lower SROCC than six of the other IQMs included in the study (VIF, FSIM, NQM, GMSD, IWSSIM, and HDRVDP). In no case did SSIM have a higher SROCC or significantly smaller residuals than RMSE. These results should be considered when choosing an IQM in future imaging studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TMI.2019.2930338 | DOI Listing |
Invest Radiol
October 2024
From the Department of Radiology and Nuclear Medicine, UKSH Lübeck, Lübeck, Germany (J.S., M.M., L.B., Y.E., J.B., M.M.S.); Institute of Medical Informatics, University of Lübeck, Lübeck, Germany (L.H., M.P.H.); Philips Research Hamburg, Hamburg, Germany (A.S., H.S.); and Institute of Interventional Radiology, UKSH Lübeck, Lübeck, Germany (M.M.S.).
Purpose: Accurate detection of central venous catheter (CVC) misplacement is crucial for patient safety and effective treatment. Existing artificial intelligence (AI) often grapple with the limitations of label inaccuracies and output interpretations that lack clinician-friendly comprehensibility. This study aims to introduce an approach that employs segmentation of support material and anatomy to enhance the precision and comprehensibility of CVC misplacement detection.
View Article and Find Full Text PDFJ Relig Health
December 2024
Department of Yoga and Spirituality, SVYASA University, Prashanti Kutiram, Vivekanand Road, Kallubalu Post Jigani, Anekal Taluk, Bangalore, 560105, India.
Spiritual lifestyles positively impact physical and mental health, which can be addressed by effective spiritual tools. This review systematically evaluates general spirituality instruments retrieved from various databases. Among the top four validated tools with strong psychometric properties, each exhibited a limitation-such as contamination, absence of subscales, or lack of confirmatory factor analysis-which impacts their broader applicability.
View Article and Find Full Text PDFObes Surg
December 2024
Nederlandse Obesitas Kliniek, 2591 XR, The Hague & Gouda, The Netherlands.
Purpose: Patient-reported outcomes are important as obesity is a chronic disease with a substantial impact. A multidisciplinary task force selected six scales (48 questions) from the validated BODY-Q questionnaire. This subset was gradually introduced and evaluated in a mandatory nationwide registry.
View Article and Find Full Text PDFEpilepsia
December 2024
Department of Neurology, Odense University Hospital, Odense, Denmark.
Objective: Idiopathic generalized epilepsy (IGE) in adults comprise juvenile myoclonic epilepsy (JME), juvenile absence epilepsy (JAE), and epilepsy with generalized tonic-clonic seizures alone (EGTCS), which are defined by their seizure types but also cover a broad endophenotype of symptoms. Controversy exists on whether adult IGE is a group of distinct diseases or a clinical spectrum of one disease. Here, we used a deeply phenotyped cohort to test the hypothesis that IGE comprises three distinct clinical entities.
View Article and Find Full Text PDFJAMA Ophthalmol
December 2024
Casey Eye Institute, Oregon Health and Science University, Portland.
Importance: Capturing high-quality images of the entire peripheral retina while minimizing the use of scleral depression could increase the quality of examinations for retinopathy of prematurity (ROP) while reducing neonatal stress.
Objective: To evaluate whether an investigational handheld ultra-widefield optical coherence tomography (UWF-OCT) device without scleral depression can be used to document high-quality images of the peripheral retina for use in ROP examinations.
Design, Setting, And Participants: This was a prospective, cross-sectional study in the neonatal intensive care unit at a single academic medical center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!