A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ring-array photoacoustic tomography for imaging human finger vasculature. | LitMetric

Ring-array photoacoustic tomography for imaging human finger vasculature.

J Biomed Opt

Kyoto University, Graduate School of Medicine, Department of Human Health Sciences, Kyoto, Japan.

Published: September 2019

For early diagnosis of rheumatoid arthritis (RA), it is important to visualize its potential marker, vascularization in the synovial membrane of the finger joints. Photoacoustic (PA) imaging, which can image blood vessels at high contrast and resolution, is expected to be a potential modality for earlier diagnosis of RA. In previous studies of PA finger imaging, different acoustic schemes, such as linear-shaped arrays, have been utilized, but these have limited detection views, rendering inaccurate reconstruction, and most of them require rotational detection. We are developing a PA system for finger vascular imaging using a ring-shaped array ultrasound (US) transducer. By designing the ring-array sensor based on simulations, using phantom experiments, it was demonstrated that we have created a system that can image small objects around 0.1 to 0.5 mm in diameter. The full width at half maximum of the slice direction of the system was within 2 mm and corresponded to that of the simulation. Moreover, we could clearly visualize healthy index finger vasculature and the location of the distal interphalangeal and proximal interphalangeal joints by PA and US echo images. In the future, this system could be used as a method for visualizing the three-dimensional vascularization of RA patients’ fingers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6997662PMC
http://dx.doi.org/10.1117/1.JBO.24.9.096005DOI Listing

Publication Analysis

Top Keywords

finger vasculature
8
finger
5
ring-array photoacoustic
4
photoacoustic tomography
4
imaging
4
tomography imaging
4
imaging human
4
human finger
4
vasculature early
4
early diagnosis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!