Surface infrared thermography, hotwire anemometry, and thermocouple surveys were performed on two new film cooling hole geometries: spiral/rifled holes and fluidic sweeping holes. The spiral holes attempt to induce large-scale vorticity to the film cooling jet as it exits the hole to prevent the formation of the kidney shaped vortices commonly associated with film cooling jets. The fluidic sweeping hole uses a passive in-hole geometry to induce jet sweeping at frequencies that scale with blowing ratios. The spiral hole performance is compared to that of round holes with and without compound angles. The fluidic hole is of the diffusion class of holes and is therefore compared to a 777 hole and Square holes. A patent-pending spiral hole design showed the highest potential of the non-diffusion type hole configurations. Velocity contours and flow temperature were acquired at discreet cross-sections of the downstream flow field. The passive fluidic sweeping hole shows the most uniform cooling distribution but suffers from low span-averaged effectiveness levels due to enhanced mixing. The data was taken at a Reynolds number of 11,000 based on hole diameter and freestream velocity. Infrared thermography was taken for blowing ratios of 1.0, 1.5, 2.0, and 2.5 at a density ratio of 1.05. The flow inside the fluidic sweeping hole was studied using 3D unsteady RANS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6750047PMC
http://dx.doi.org/10.1115/1.4032839DOI Listing

Publication Analysis

Top Keywords

fluidic sweeping
16
film cooling
12
sweeping hole
12
hole
11
sweeping holes
8
infrared thermography
8
blowing ratios
8
spiral hole
8
holes
7
sweeping
6

Similar Publications

The emergence of nanofluidic memristors has made a giant leap to mimic the neuromorphic functions of biological neurons. Here, we report neuromorphic signaling using Angstrom-scale funnel-shaped channels with poly-l-lysine (PLL) assembled at nano-openings. We found frequency-dependent current-voltage characteristics under sweeping voltage, which represents a diode in low frequencies, but it showed pinched current hysteresis as frequency increases.

View Article and Find Full Text PDF

Magnetic-field-induced propulsion of jellyfish-inspired soft robotic swimmers.

Phys Rev E

January 2023

Micromechanics Group, Zernike Institute for Advanced Materials, University of Groningen, Netherlands.

The multifaceted appearance of soft robots in the form of swimmers, catheters, surgical devices, and drug-carrier vehicles in biomedical and microfluidic applications is ubiquitous today. Jellyfish-inspired soft robotic swimmers (jellyfishbots) have been fabricated and experimentally characterized by several researchers that reported their swimming kinematics and multimodal locomotion. However, the underlying physical mechanisms that govern magnetic-field-induced propulsion are not yet fully understood.

View Article and Find Full Text PDF

We present a nanomechanical platform for real-time quantitative label-free detection of target biomolecules in a liquid environment with mass sensitivity down to few pg. Newly fabricated arrays of up to 18 cantilevers are integrated in a micromachined fluidic chamber, connected to software-controlled fluidic pumps for automated sample injections. We discuss two functionalization approaches to independently sensitize the interface of different cantilevers.

View Article and Find Full Text PDF

Biofouling of tubular fluidic devices limits the stability, accuracy, and long-term uses of lab-on-a-chip systems. Healthcare-associated infection by biofilm formations on body-indwelling and extracorporeal tubular medical devices is also a major cause of mortality and morbidity in patients. Although diverse antifouling techniques have been developed to prevent bacterial contamination of fluidic devices based on antimicrobial materials or nanoscale architectures, they still have limitations in biocompatibility, long-term activity, and durability.

View Article and Find Full Text PDF

Evaluation of rheological behaviour of flowable dental composites reinforced with low aspect ratio micro-sized glass fibres.

Dent Mater

January 2021

School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia; ARC Centre for Automated Manufacture of Advanced Composites, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia. Electronic address:

Objective: Experimental investigation is carried out to determine the flowability and stickiness of the developed composite material for dental restoration containing low aspect ratio (AR ≤ 100) surface treated micro-sized glass fibres.

Methods: Specimens are manufactured by mixing low AR (50/70/100) micro-sized glass fibres with two different weight fractions (5%/10%) into UDMA/TEGDMA based resin. Particulate filler composite (PFC) containing 55% glass fillers is used as the control group.

View Article and Find Full Text PDF