We introduce a new imaging technique to improve visualisation of stent apposition after endovascular treatment of brain aneurysms employing high-resolution cone beam CT and three-dimensional digital subtraction angiography. After performing a stent-assisted coil embolisation of brain aneurysm, the image datasets were processed with a metal artefact reduction software followed by the automated image fusion programmes. Two patients who underwent aneurysm coiling using a Neuroform stent were evaluated. The reconstructed 3D images showed a detailed structure of the stent struts and identified malappositions of the deployed stents. Case 1 showed good apposition on the outer curvature side of the carotid siphon, while the inner curvature side showed prominent malapposition. Case 2, with multiple aneurysms, showed good apposition on both outer and inner curvature sides, although inward prolapse of the struts was observed. This new imaging technique may help evaluate stent apposition after the endovascular aneurysm treatment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6754653PMC
http://dx.doi.org/10.1136/bcr-2019-230687DOI Listing

Publication Analysis

Top Keywords

stent apposition
12
high-resolution cone
8
cone beam
8
metal artefact
8
artefact reduction
8
reduction software
8
image fusion
8
aneurysm treatment
8
imaging technique
8
apposition endovascular
8

Similar Publications

The double-kissing (DK) culotte technique is a modification of the culotte technique that employs initial kissing balloon inflation after first stent implantation. The DK culotte technique may improve strut apposition and procedural outcomes; however, data on its efficacy and safety remain limited. This study aimed to investigate the short-term outcomes of bifurcation percutaneous coronary intervention (PCI) using the DK culotte technique compared with those of the culotte technique in patients with acute coronary syndrome (ACS).

View Article and Find Full Text PDF

Calcified plaque modification during percutaneous coronary revascularization.

Prog Cardiovasc Dis

December 2024

The Christ Hospital Heart & Vascular Institute and The Carl and Edyth Lindner Center for Research and Education, Cincinnati, Ohio, USA.. Electronic address:

The presence and severity of calcified coronary plaque negatively impacts angiographic and clinical outcomes following percutaneous coronary intervention (PCI). Severe coronary calcification is associated with suboptimal stent delivery, deployment, apposition and expansion which can lead to in-stent restenosis and/or thrombosis. Severe coronary calcification is associated with incremental hazard for adverse clinical events, including death, during 5-10 years following PCI despite the use of new generation drug- eluting stents.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates the effectiveness of different balloon treatments after rotational atherectomy (RA) for calcified coronary lesions, focusing on whether modified balloons (MB) improve outcomes compared to plain balloon angioplasty (BA).
  • - A meta-analysis of nine studies involving 1,024 patients found no significant differences in major adverse cardiovascular events, all-cause mortality, or target lesion revascularization between the RA + BA and RA + MB groups overall.
  • - However, the analysis revealed that for patients with severely calcified lesions, the RA + MB group experienced significantly fewer major adverse cardiovascular events without increasing procedural complications.
View Article and Find Full Text PDF

Background: Iatrogenic vertebral artery injury during surgery can cause pseudoaneurysm, hemorrhage, thrombosis, ischemia, or death. Strategies to prevent cerebrovascular embolic complications include surgical ligation, endovascular stenting, and/or antiplatelet therapy.

Observations: A 73-year-old female with a known right vertebral artery occlusion underwent a C2-3 laminectomy, complicated by left vertebral artery injury and occlusion with subsequent posterior circulation ischemia.

View Article and Find Full Text PDF

Background: Virtual simulation is increasingly used for aneurysm treatment. This study aimed to explore whether mechanical behavior biomarkers of the Woven EndoBridge (WEB) device as computed by Sim&Size simulation software were associated with aneurysmal occlusion status at follow-up.

Methods: Consecutive patients with aneurysms treated with WEB were retrospectively enrolled (January 2014 to December 2021).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!