We introduce a new imaging technique to improve visualisation of stent apposition after endovascular treatment of brain aneurysms employing high-resolution cone beam CT and three-dimensional digital subtraction angiography. After performing a stent-assisted coil embolisation of brain aneurysm, the image datasets were processed with a metal artefact reduction software followed by the automated image fusion programmes. Two patients who underwent aneurysm coiling using a Neuroform stent were evaluated. The reconstructed 3D images showed a detailed structure of the stent struts and identified malappositions of the deployed stents. Case 1 showed good apposition on the outer curvature side of the carotid siphon, while the inner curvature side showed prominent malapposition. Case 2, with multiple aneurysms, showed good apposition on both outer and inner curvature sides, although inward prolapse of the struts was observed. This new imaging technique may help evaluate stent apposition after the endovascular aneurysm treatment.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6754653 | PMC |
http://dx.doi.org/10.1136/bcr-2019-230687 | DOI Listing |
J Clin Med
December 2024
1st Department of Cardiology, University of Medical Sciences, 61-848 Poznan, Poland.
The double-kissing (DK) culotte technique is a modification of the culotte technique that employs initial kissing balloon inflation after first stent implantation. The DK culotte technique may improve strut apposition and procedural outcomes; however, data on its efficacy and safety remain limited. This study aimed to investigate the short-term outcomes of bifurcation percutaneous coronary intervention (PCI) using the DK culotte technique compared with those of the culotte technique in patients with acute coronary syndrome (ACS).
View Article and Find Full Text PDFProg Cardiovasc Dis
December 2024
The Christ Hospital Heart & Vascular Institute and The Carl and Edyth Lindner Center for Research and Education, Cincinnati, Ohio, USA.. Electronic address:
The presence and severity of calcified coronary plaque negatively impacts angiographic and clinical outcomes following percutaneous coronary intervention (PCI). Severe coronary calcification is associated with suboptimal stent delivery, deployment, apposition and expansion which can lead to in-stent restenosis and/or thrombosis. Severe coronary calcification is associated with incremental hazard for adverse clinical events, including death, during 5-10 years following PCI despite the use of new generation drug- eluting stents.
View Article and Find Full Text PDFJ Clin Med
November 2024
Heart and Vascular Centre, Semmelweis University, 1122 Budapest, Hungary.
J Neurosurg Case Lessons
October 2024
Cooper Medical School of Rowan University, Camden, New Jersey.
Background: Iatrogenic vertebral artery injury during surgery can cause pseudoaneurysm, hemorrhage, thrombosis, ischemia, or death. Strategies to prevent cerebrovascular embolic complications include surgical ligation, endovascular stenting, and/or antiplatelet therapy.
Observations: A 73-year-old female with a known right vertebral artery occlusion underwent a C2-3 laminectomy, complicated by left vertebral artery injury and occlusion with subsequent posterior circulation ischemia.
J Neurointerv Surg
November 2024
Neuroradiology, Gui de Chauliac, University Hospital Centre of Montpellier, Montpellier, France.
Background: Virtual simulation is increasingly used for aneurysm treatment. This study aimed to explore whether mechanical behavior biomarkers of the Woven EndoBridge (WEB) device as computed by Sim&Size simulation software were associated with aneurysmal occlusion status at follow-up.
Methods: Consecutive patients with aneurysms treated with WEB were retrospectively enrolled (January 2014 to December 2021).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!