Background: Fluorescence optical imaging (FOI) enables visualization of inflammation in the hands in rheumatic joint diseases with currently a lack of long-term follow-up studies.

Objective: To investigate FOI for treatment monitoring in a homogenous cohort of patients with early (disease duration < 2 years) and active (DAS28 > 3.2) RA over a period of 12 months.

Methods: Thirty-five RA patients (24 (68.6%) females, mean age 53.3 years (SD 13.6)) were investigated clinically by DAS28, tender joint count (TJC) and swollen joint count (SJC) and by FOI in phases 1-3 and PrimaVistaMode (PVM) before therapy change and after 12 months. The FOI activity score (FOIAS) was calculated based on individual joint scores from 0 to 3 in 30 joints per patient, adding up to a sum score (0-90).

Results: We found a statistically significant reduction of FOIAS in phase 1 from baseline (median 5.0, IQR 24.96) to follow-up (median 1.0, IQR 4.0) in all patients (p = 0.0045), both in responders and non-responders according to EULAR response criteria by DAS28. Statistically significant reductions over 12 months were found for median DAS28(ESR) 5.61 to 3.31, TJC 7.0 to 1.0, and SJC 5.0 to 1.0 (each p <  0.001). No statistically significant correlations were detected between the FOIAS change in phase 1 and DAS28(ESR), TJC, or SJC. Correlations between the other phases and clinical outcomes were weak to moderate.

Conclusion: Reduced early enhancement in FOI phase 1 can be observed in clinically responding and non-responding early RA patients under treatment. Regarding potential marker performance, FOI probably shows a reduction of inflammation more objectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749637PMC
http://dx.doi.org/10.1186/s13075-019-1989-5DOI Listing

Publication Analysis

Top Keywords

fluorescence optical
8
optical imaging
8
treatment monitoring
8
patients early
8
joint count
8
median iqr
8
imaging treatment
4
patients
4
monitoring patients
4
early active
4

Similar Publications

Bio-Layer Interferometry (BLI) is a technique that uses optical biosensing to analyze interactions between molecules. The analysis of molecular interactions is measured in real-time and does not require fluorescent tags. BLI uses disposable biosensors that come in a variety of formats to bind different ligands including biotin, hexahistidine, GST, and the Fc portion of antibodies.

View Article and Find Full Text PDF

Investigating Complexin-Membrane Interactions Using NMR and Optical Methods.

Methods Mol Biol

January 2025

Department of Biochemistry, Weill Cornell Medicine, New York, NY, USA.

Complexins are a family of small presynaptic proteins that regulate neurotransmitter release at nerve terminals and are highly conserved in evolution. While direct interactions with SNARE proteins are critical for all complexin functions, binding of their disordered C-terminal domains (CTD) to membranes, especially to synaptic vesicle membranes, is essential for the ability of complexin to inhibit vesicle release. Furthermore, while some complexin CTDs possess an endogenous affinity for membranes, other complexin isoforms are subject to lipidation at their C-termini, which is presumed to confer additional membrane binding.

View Article and Find Full Text PDF

Mind the leaf anatomy while taking ground truth with portable chlorophyll meters.

Sci Rep

January 2025

Department of Plant Experimental Biology, Faculty of Science, Charles University, Viničná 5, 12800, Prague, Czech Republic.

A wide range of portable chlorophyll meters are increasingly being used to measure leaf chlorophyll content as an indicator of plant performance, providing reference data for remote sensing studies. We tested the effect of leaf anatomy on the relationship between optical assessments of chlorophyll (Chl) against biochemically determined Chl content as a reference. Optical Chl assessments included measurements taken by four chlorophyll meters: three transmittance-based (SPAD-502, Dualex-4 Scientific, and MultispeQ 2.

View Article and Find Full Text PDF

Anthropogenic activities have led to increased stress on our marine and other aquatic environments. There is a pressing need to monitor, measure, understand and mitigate causes of these pressures. This paper presents a novel optical head for monitoring and measuring marine based optical phenomena.

View Article and Find Full Text PDF

Visible-Light-Driven Fluorescence Turn-on Photoswitches With Near Quantitative Photocyclization Yield.

Adv Sci (Weinh)

January 2025

School of Materials Science and Engineering, Zhengzhou University, No.100 Science Avenue, Zhengzhou, 450001, P. R. China.

Photoswitchable fluorescent materials have gained significant attention for their potential in advanced information encryption and anti-counterfeiting applications. However, the common use of UV light to trigger the isomerization processes leads to photobleaching and poor fatigue resistance. Visible-light-driven fluorescent photoswitches are highly desirable, but achieving high cyclization yield remains challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!