Nerve excitability differences in slow and fast motor axons of the rat: more than just .

J Neurophysiol

Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada.

Published: October 2019

The objective was to determine biophysical differences between fast and slow motor axons using threshold tracking and demonstrate confounds related to anesthetic. Nerve excitability of motor axons innervating the slow-twitch soleus (SOL) and fast-twitch tibialis anterior (TA) muscles was tested. The experiments were conducted with pentobarbital sodium (SP) anesthetic and compared with previous results that used ketamine-xylazine (KX). Nerve excitability indices measured with SP show definitive differences between TA and SOL motor axons that extend beyond previous reports. Nerve excitability indices sensitive to changes in indicated an increase in SOL axons compared with TA axons [e.g., S3 = 7.949 (df = 10), < 0.001; hyperpolarizing threshold electrotonus (90-100 ms), = 2.659 (df = 20); = 0.01; hyperpolarizing slope, = 4.308 (df = 19); < 0.001]. SOL axons also had a longer strength-duration time constant [ = 3.35 (df = 20); = 0.003] and a longer and larger magnitude relative refractory period [RRP (ms) = 3.53 (df = 12); = 0.004; Refractoriness at 2 ms, = 0.0055 (df = 9); = 0.006]. Anesthetic choice affected many measures of peripheral nerve excitability with differences most apparent in tests of threshold electrotonus and recovery cycle. For example, recovery cycle with KX lacked a clear superexcitable and late subexcitable period. We conclude that KX had a confounding effect on nerve excitability results consistent with ischemic depolarization. Results using SP revealed the full extent of differences in nerve excitability measures between putative slow and fast motor axons of the rat. These results provide empirical evidence, beyond conduction velocity, that the biophysical properties of motor axons vary with the type of muscle fiber innervated. These differences suggest that fast axons may be predisposed to dysfunction during hyperpolarizing stresses, e.g., electrogenic sodium pumping following sustained impulse conduction. Nerve excitability testing is a tool used to provide insight into the properties of ion channels in peripheral nerves. It is used clinically to assess pathophysiology of axons. Researchers customarily think of motor axons as homogeneous; however, we demonstrate there are clear differences between fast and slow axons in the rat. This is important for interpreting results with selective motor neuronopathy, like aging where fast axons are at high risk of degeneration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6843099PMC
http://dx.doi.org/10.1152/jn.00269.2019DOI Listing

Publication Analysis

Top Keywords

nerve excitability
32
motor axons
28
axons
14
axons rat
12
differences fast
12
nerve
8
excitability differences
8
slow fast
8
motor
8
fast motor
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!