Post-bariatric patients undergoing abdominoplasty have a relatively high risk of complications due to residual obesity and major comorbidities. Also, conventional electrosurgery and the associated thermal tissue damage may compromise outcomes. This retrospective randomised clinical study evaluated the effect of low-thermal plasma dissection device (PEAK [pulsed electron avalanche knife] PlasmaBlade) in comparison with conventional electrosurgery. A total of 52 post-bariatric patients undergoing abdominoplasty were randomised to PEAK PlasmaBlade (n = 26) and to monopolar electrosurgery (n = 26). Wounds of 20 patients per group were examined histologically for acute thermal injury depth. In PEAK PlasmaBlade incisions, acute thermal damage was significantly reduced compared with standard of care (40% vs 75%; P = .035). Also, acute thermal injury depth from PEAK PlasmaBlade was less than that from electrosurgery (2780 μm vs 4090 μm). Significantly less total complication rate (30.8% vs 69.2%; P = .012) was found by PEAK PlasmaBlade compared with electrosurgery. Moreover, the PEAK PlasmaBlade showed less than half as many wound healing problems (19.2% vs 46.2%; P = .075), far fewer secondary bleeding (7.7% vs 30.8%; P = .075), and no seroma compared with four seroma with the standard of care (0% vs 15.4%; P = .11). PEAK PlasmaBlade appears to be superior to traditional monopolar electrosurgery for post-bariatric abdominoplasty, because it demonstrated significantly less tissue damage, less total complication rate, and fewer postoperative seroma resulting in faster wound healing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7949000PMC
http://dx.doi.org/10.1111/iwj.13221DOI Listing

Publication Analysis

Top Keywords

peak plasmablade
28
conventional electrosurgery
12
acute thermal
12
low-thermal plasma
8
plasma dissection
8
dissection device
8
peak
8
device peak
8
plasmablade
8
electrosurgery post-bariatric
8

Similar Publications

(1) : DIEP-based breast reconstruction necessitates wide undermining at the abdominal donor site, creating large wound areas. Flap harvesting is usually conducted using electrosurgical dissection devices. This study sought to compare the clinical outcomes in patients after using the PEAK PlasmaBlade (PPB) versus monopolar electrocautery (MPE).

View Article and Find Full Text PDF

PlasmaBlade-assisted surgical septal myectomy: technique and our experience.

Front Cardiovasc Med

January 2024

Department of Cardiothoracic Surgery, Mayo Clinic, Jacksonville, FL, United States.

Background: The pulsed-electron avalanche knife (PEAK) PlasmaBlade provides an atraumatic, scalpel-like cutting precision and electrocautery-like hemostasis. PlasmaBlade operates near body temperature, and its long, thin, and malleable tip can overcome the limitations of a surgical knife. In this study, we aimed to evaluate our clinical experience and histopathological outcomes of septal myectomy using PlasmaBlade.

View Article and Find Full Text PDF

Objective(s): Coblation, or radiofrequency ablation, and pulsed-electron avalanche knife (PEAK) plasmablade are newer approaches for tonsillectomy that reduce exposure to thermal heat. This study aims to describe and compare adverse events related to these devices for tonsillectomy.

Study Design: Retrospective cross-sectional study.

View Article and Find Full Text PDF

The pulse-electron avalanche knife (PEAK) PlasmaBlade 3.0 and 4.0 (Medtronic, Minneapolis, MN) is an electrosurgical technology that is widely used in surgery.

View Article and Find Full Text PDF

: Permanent pacemaker implantation (PPI) is frequently required following transcatheter aortic valve replacement (TAVR). Dual antiplatelet therapy (DAPT) or oral anticoagulation therapy (OAK) is often necessary in these patients since they are at higher risk of thromboembolic events due to TAVR implantation, high incidence of coronary artery diseases (CAD) with the necessity of coronary intervention, and high rate of atrial fibrillation with the need of stroke prevention. We sought to evaluate the safety, efficiency, and clinical outcomes of early PPI following TAVR using the PlasmaBlade™ (Medtronic Inc.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!