Endovascular Treatment of Complex Aneurysms with the Use of Covera Stent Grafts.

J Vasc Interv Radiol

Department of Vascular Surgery, Université de Bordeaux, University Hospital of Bordeaux, Bordeaux, France. Electronic address:

Published: December 2019

Purpose: To characterize the short-term results of a newly available self-expanding covered stent (Covera; CR Bard Peripheral Vascular Inc., Murray Hill, New Jersey) for the reconstruction of target vessels in complex aneurysms.

Materials And Methods: From August 2017 to November 2018, this self-expanding covered stent was used in 17 patients (mean 72.6 ± 7.6 years of age) during endovascular aneurysm repair (EVAR) with hypogastric preservation (11.8%), branched EVAR (29.4%), fenestrated (F)-EVAR (17.6%), chimney + F-EVAR (11.8%), or chimney EVAR (29.4%). In more than 48 stented arteries (2.8 ± 1.1/patient), 25 were preserved using this self-expanding covered stent.

Results: All target vessels were successfully preserved. There was no 30-day mortality and 1 in-hospital death. Intraoperative aneurysm exclusion was successful in 14 patients (82.4%) with a perioperative technical success rate of 82.4%. The actuarial survival rate was 93.8% at 6 months and 85.9% at 12 months. Aneurysm sac regression of >5 mm was observed in 4 cases (23.5%), and the sac remained stable in the remaining patients (13 cases [76.5%]). At 12 months, the primary clinical success rate was 76.5%, and assisted primary clinical success rate was 82.4%. No type 3 endoleak was related to a disruption of the reconstruction with the self-expanding covered stent.

Conclusions: This new self-expanding covered stent provides good short-term patency in chimneys, branches, or fenestrations. Larger series with long-term follow-up are required to determine if the stent can sustain the mechanical stress to which it will be submitted in these repairs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2019.05.004DOI Listing

Publication Analysis

Top Keywords

self-expanding covered
20
covered stent
12
success rate
12
target vessels
8
evar 294%
8
rate 824%
8
primary clinical
8
clinical success
8
stent
5
self-expanding
5

Similar Publications

Esophago-jejunal anastomoses fistula could be mortal. Currently there is a wide therapeutic measure ranging from conservative management, endoscopic therapy and surgery. Endoscopic management has been positioned above other strategies due to minimal invasion which improves survival and reduces mortality.

View Article and Find Full Text PDF

The management of gastrointestinal anastomotic leaks post surgery is a considerable challenge, characterized by elevated morbidity and mortality, particularly in cases of esophageal-jejunal anastomotic leaks. Diverse endoscopic intervention techniques have been utilized with enhanced success. We present a case where a 57-year-old patient with Siewert type II esophageal cardia cancer underwent endoscopic deployment of a fully covered stent into a fistula resulting from anastomotic leakage, following a laparoscopic proximal gastrectomy with Roux-en-Y and double tract reconstruction.

View Article and Find Full Text PDF

Background And Aims: Fully covered self-expandable metallic stents (FCSEMS) are often used in the management of post-sphincterotomy bleeding which is refractory to conventional endoscopic treatments. In this meta-analysis, we have evaluated the efficacy and safety of FCSEMS in the management of post-sphincterotomy bleeding.

Methods: We reviewed several databases from inception to November 6, 2024 to identify studies that evaluated the efficacy, and/or safety of FCSEMS in the management of post sphincterotomy bleeding.

View Article and Find Full Text PDF

Background: Covered stent correction for a sinus venosus atrial septal defect (SVASD) was first performed in 2009. This innovative approach was initially viewed as experimental and was reserved for highly selected patients with unusual anatomic variants. In 2016, increasing numbers of procedures began to be performed, and in several centers, it is now offered as a standard of care option alongside surgical repair.

View Article and Find Full Text PDF

Background And Aims: Self-expanding metal stents (SEMSs) are effective for symptom palliation in patients with esophageal obstruction. However, their placement can lead to adverse events such as stent migration and restenosis. A novel fully covered SEMS (FCSEMS) with antimigration properties has been developed to address these issues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!