Temporal speckle-averaging of optical coherence tomography volumes for cellular resolution neuronal and vascular retinal imaging.

Neurophotonics

University of California Davis, Department of Cell Biology and Human Anatomy, UC Davis Eye-Pod Small Animal Ocular Imaging Laboratory, Davis, California, United States.

Published: October 2019

AI Article Synopsis

  • Recent advancements have allowed visualization of transparent cell bodies in the retina using optical coherence tomography (OCT), leading to exploration of this technique in mice, crucial for studying retinal diseases.
  • The study developed a framework for temporal speckle-averaging (TSA) applied to mouse retinal data, showing minimal eye motion under anesthesia which reduces motion artifacts.
  • The results highlight enhanced imaging capabilities without needing adaptive optics, revealing new structures in the retina and improving signal quality through the TSA method.

Article Abstract

It has been recently demonstrated that structures corresponding to the cell bodies of highly transparent cells in the retinal ganglion cell layer could be visualized noninvasively in the living human eye by optical coherence tomography (OCT) via temporal averaging. Inspired by this development, we explored the application of volumetric temporal averaging in mice, which are important models for studying human retinal diseases and therapeutic interventions. A general framework of temporal speckle-averaging (TSA) of OCT and optical coherence tomography angiography (OCTA) is presented and applied to mouse retinal volumetric data. Based on the image analysis, the eyes of mice under anesthesia exhibit only minor motions, corresponding to lateral displacements of a few micrometers and rotations of a fraction of 1 deg. Moreover, due to reduced eye movements under anesthesia, there is a negligible amount of motion artifacts within the volumes that need to be corrected to achieve volume coregistration. In addition, the relatively good optical quality of the mouse ocular media allows for cellular-resolution imaging without adaptive optics (AO), greatly simplifying the experimental system, making the proposed framework feasible for large studies. The TSA OCT and TSA OCTA results provide rich information about new structures previously not visualized in living mice with non-AO-OCT. The mechanism of TSA relies on improving signal-to-noise ratio as well as efficient suppression of speckle contrast due to temporal decorrelation of the speckle patterns, enabling full utilization of the high volumetric resolution offered by OCT and OCTA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6732665PMC
http://dx.doi.org/10.1117/1.NPh.6.4.041105DOI Listing

Publication Analysis

Top Keywords

optical coherence
12
coherence tomography
12
temporal speckle-averaging
8
temporal averaging
8
tsa oct
8
temporal
5
optical
4
speckle-averaging optical
4
tomography volumes
4
volumes cellular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!