Value of contrast-enhanced ultrasound for preoperative assessment of liver reserve function in patients with liver tumors.

PLoS One

Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan City, Hubei Province, China.

Published: March 2020

This study aimed to investigate the value of contrast-enhanced ultrasound (CEUS) for preoperative assessment of liver reserve function in patients with liver tumors. The indocyanine green (ICG) clearance tests and CEUS examinations of 45 noncirrhotic patients with liver tumors were performed prior to liver resection. Parameters time to peak (TtoPk), arrival time (Atm) as well as perfusion parameters A, k and A x k were generated from time-intensity curve (TIC) of CEUS. The correlation analyses of the ICG clearance per unit time (ICGK) and the retention rate at 15 min (ICGR15) with TtoPk, Atm, A, k and A x k were performed, and the diagnostic ability as well as optimal cut-off values of TtoPk and Atm for differentiating patients with ICGR15>10% from ICGR15<10% were analyzed. There were significant correlations of ICGK with TtoPk and Atm, and the correlation coefficients were 0.363 (p = 0.014) and -0.482 (p = 0.001), respectively. Significant correlations of ICGR15 with TtoPk and Atm were revealed, and the correlation coefficients were -0.416 (p = 0.004) and 0.303 (p = 0.043), respectively. No correlation of ICGK or ICGR15 with A, k and A x k was found in this study. There were significant differences in TtoPk and Atm between patients with ICGR15>10% and ICGR15<10% (p = 0.028 and p = 0.026, respectively). TtoPk and Atm both had good diagnostic abilities in diagnosing patients with ICGR15>10% verusus ICGR15<10% (AUROC = 0.711 and 0.721, respectively). For ICGR15>10% vs ICGR15, the optimal cut-off values of TtoPk and Atm were 13.307 s and 11.007 s, respectively, while the sensitivity and specificity were 75.0% and 72.7%, 60.6% and 75.0%, respectively. This study revealed that CEUS has the potential to be a new method to evaluate the liver reserve function of patients. With the optimal cut-off values of TtoPk and Atm, qualitative assessment of patients with ICGR15>10% could be more easily achieved by CEUS with good diagnostic abilities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6748425PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0222514PLOS

Publication Analysis

Top Keywords

ttopk atm
16
liver reserve
12
reserve function
12
function patients
12
patients liver
12
liver tumors
12
optimal cut-off
12
cut-off values
12
values ttopk
12
contrast-enhanced ultrasound
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!