Research on elastic recoil and restoration of vessel pulsatility of Zn-Cu biodegradable coronary stents.

Biomed Tech (Berl)

Department of Interventional and Vascular Surgery, The Tenth People's Hospital of Shanghai, Tongji University, Shanghai 200072, P.R. China.

Published: April 2020

Coronary stents made of zinc (Zn)-0.8 copper (Cu) (in wt%) alloy were developed as biodegradable metal stents (Zn-Cu stents) in this study. The mechanical properties of the Zn-Cu stents and the possible gain effects were characterized by in vitro and in vivo experiments compared with 316L stainless steel stents (316L stents). Young's modulus of the as-extruded Zn-0.8Cu alloy and properties of the stents, including their intrinsic elastic recoil, stent trackability were evaluated compared with 316L stents. In vivo study was also conducted to evaluate restoration of pulsatility of vessel segment implanted stents. Both Zn-Cu stents and 316L stents have good acute lumen gain. By comparison, the advantages of Zn-Cu stents are as follows: (I) Zn-Cu stents have less intrinsic elastic recoil than 316L stents; (II) stent trackability indicates that Zn-Cu stents have a smaller push force when passing through curved blood vessels, which may cause less mechanical stimulation to blood vessels; (III) in vivo study suggests that Zn-Cu stents implantation better facilitates the recovery of vascular pulsatility.

Download full-text PDF

Source
http://dx.doi.org/10.1515/bmt-2019-0025DOI Listing

Publication Analysis

Top Keywords

zn-cu stents
28
stents
17
316l stents
16
elastic recoil
12
stents zn-cu
12
zn-cu
8
coronary stents
8
compared 316l
8
stents 316l
8
intrinsic elastic
8

Similar Publications

In this study, biodegradable Zn-Cu-Mn alloy stents were implanted into porcine coronary artery for 18 months, and the in vivo biosafety and efficacy as well as the degradation behavior were systematically studied. Results showed a rapid endothelialization of the target vessel was achieved at 1 month post-implantation. Although the lumen diameter loss and local inflammation were observed at the early stage, the stented blood vessel could gradually recover with time.

View Article and Find Full Text PDF

Effect of TiC Nanoparticles on a Zn-Al-Cu System for Biodegradable Cardiovascular Stent Applications.

ACS Biomater Sci Eng

May 2024

Department of Mechanical and Aerospace Engineering, Samueli School of Engineering, University of California, Los Angeles, California 90095, United States.

Despite being a weaker metal, zinc has become an increasingly popular candidate for biodegradable implant applications due to its suitable corrosion rate and biocompatibility. Previous studies have experimented with various alloy elements to improve the overall mechanical performance of pure Zn without compromising the corrosion performance and biocompatibility; however, the thermal stability of biodegradable Zn alloys has not been widely studied. In this study, TiC nanoparticles were introduced for the first time to a Zn-Al-Cu system.

View Article and Find Full Text PDF

In this work, an investigation on the Zn-Cu alloy coated with heparin was conducted in order to explore the potentiality of its application as a feasible alternative for biodegradable implants, with the specific goal of addressing the issue of encrustation in the urinary system. The stability of the nanoparticles were characterized by dynamic light scattering. Typical surface characterization such as X-ray photoelectron spectroscopy, scanning electron microscopy, and atomic force microscopy were used to demonstrate a successful immobilization of the NPs.

View Article and Find Full Text PDF

Fabrication and characterization of biodegradable Zn-Cu-Mn alloy micro-tubes and vascular stents: Microstructure, texture, mechanical properties and corrosion behavior.

Acta Biomater

October 2022

National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China. Electronic address:

Zinc (Zn) alloys are a promising biodegradable material for vascular stent applications. This study aimed to fabricate biodegradable Zn-2.0Cu-0.

View Article and Find Full Text PDF

Biodegradable Zn-Cu-Mn alloy with suitable mechanical performance and in vitro degradation behavior as a promising candidate for vascular stents.

Biomater Adv

February 2022

National Engineering Research Center of Light Alloy Net Forming & State Key Laboratory of Metal Matrix Composite, Shanghai Jiao Tong University, Shanghai 200240, China. Electronic address:

Recently, zinc (Zn) alloy has been considered as a promising biodegradable material due to its excellent physiological degradable behavior and acceptable biocompatibility. However, poor mechanical performance limits its application as vascular stents. In this study, novel biodegradable Zn-2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!