Objective: Neonatal hydrocephalus remains a difficult condition to manage, due to high failure rates among all management strategies. Neurosurgeons commonly manage hydrocephalus with ventriculoperitoneal shunt (VPS) implantation, and valves of variable sizes and profiles are available for implantation. This study examines primary ventricular shunt valve implantation complication rates based on valve profiles in pediatric patients with hydrocephalus.

Methods: This study retrospectively reviews pediatric patients younger than 1 year of age who underwent ventricular shunt placement at a single institution from January 2001 to January 2017. Patients were classified by valve profile and categorized as either ultrasmall valves or regular-sized valves. Time until complication and type of complication were studied.

Results: A total of 156 patients met the inclusion criteria. Forty-eight (31%) patients received an ultrasmall shunt valve, while 108 patients received a regular valve. On average, patients undergoing ultrasmall valve placement were younger (2.1 months) than patients undergoing placement of regular valves (3.1 months) (P = 0.03). The overall complication rate within 2 years of VPS placement was 37.5% in patients with the ultrasmall valve and 41.7% in the regular valve population. There was no difference in 1-year shunt survival rate between the 2 cohorts.

Conclusion: Our review did not find a significant difference in complication rates between ultrasmall and regular valves in patients under 1 year of age. However, the etiology of shunt malfunction did differ between the groups. This work further supports evidence suggesting a surgeon's preference for shunt hardware alone does not significantly impact outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2019.09.043DOI Listing

Publication Analysis

Top Keywords

ultrasmall valve
12
patients
10
valve
9
neonatal hydrocephalus
8
valve implantation
8
ventricular shunt
8
shunt valve
8
complication rates
8
pediatric patients
8
year age
8

Similar Publications

Infant hydrocephalus: what valve first?

Childs Nerv Syst

November 2021

Department of Neurosurgery, Alder Hey Children's NHS Trust, Liverpool, UK.

Purpose: To review the use of different valve types in infants with hydrocephalus, in doing so, determining whether an optimal valve choice exists for this patient cohort.

Methods: We conducted (1) a literature review for all studies describing valve types used (programmable vs. non-programmable, valve size, pressure) in infants (≤ 2 years) with hydrocephalus, (2) a review of data from the pivotal BASICS trial for infant patients and (3) a separate, institutional cohort study from Alder Hey Children's Hospital NHS Foundation Trust.

View Article and Find Full Text PDF

Objective: Neonatal hydrocephalus remains a difficult condition to manage, due to high failure rates among all management strategies. Neurosurgeons commonly manage hydrocephalus with ventriculoperitoneal shunt (VPS) implantation, and valves of variable sizes and profiles are available for implantation. This study examines primary ventricular shunt valve implantation complication rates based on valve profiles in pediatric patients with hydrocephalus.

View Article and Find Full Text PDF

Ferumoxytol-enhanced MRI in the peripheral vasculature.

Clin Radiol

January 2019

Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA; Department of Radiology, Veterans Affairs Medical Center, University of California, San Francisco, CA, USA.

Ferumoxytol is a promising non-gadolinium-based contrast agent with numerous varied magnetic resonance imaging applications. Previous reviews of vascular applications have focused primarily on cardiac and aortic applications. After considering safety concerns and technical issues, the objective of this paper is to explore peripheral applications for ferumoxytol-enhanced magnetic resonance angiography (MRA) and venography (MRV) in the upper and lower extremities.

View Article and Find Full Text PDF

Power-free, digital and programmable dispensing of picoliter droplets using a Digit Chip.

Lab Chip

April 2017

Institute for Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada.

There is a growing need for power-free methods to manipulate small volumes of liquids and thereby enable use of diagnostic assays in resource-limited settings. Most existing self-powered devices provide analog manipulation of fluids using paper, capillary or pressure-driven pumps. These strategies are well-suited to manipulating larger micro- and milliliter-scale volumes at constant flow rates; however, they fail to enable the manipulation of nanoliter and picoliter volumes required in assays using droplets, capillary sampling (e.

View Article and Find Full Text PDF

Aim: To evaluate the effect of shunt selection on the rate of shunt revision due to early shunt complications in neonatal myelomeningocele-associated hydrocephalus.

Material And Methods: The data of 157 neonatal myelomeningocele cases in three pediatric neurosurgery centers (Ankara University, Kocaeli University, Selcuk University) who underwent shunt surgery at the time of myelomeningocele repair between 2000 and 2014 were retrospectively analyzed. Clinical features of the patients, shunt types, and early shunt complications within the first three months were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!