Background: Bone quality in hip fractures is poor and there is a need to not only correctly position metalwork within the femoral head, but also for implants to resist cut-out. New implant designs may help to reduce metalwork cut-out, leading to fewer failures of fixation. This study compared the cut-out strength of a Dynamic Hip Screw (DHS) to that of an X-Bolt® (X-Bolt Orthopaedics, Dublin, Ireland) implant in an osteoporotic Sawbones® (Sawbones, Vashon Island, WA) model.

Methods: An unstable fracture model (AO 31-A2) was created using low-density 5 pound per cubic foot (pcf) Sawbones®. The DHS and X-Bolts® were inserted into the Sawbones® femoral head at Tip-Apex Distances (TAD) of 10mm, 15mm, 20mm, 25mm, 30mm and 40mm. A cyclic-loading Instron® machine (Instron Corp., Norwood, MA) pushed the bone at a compression rate of 5mm per minute at a 20-degree angle to the axis of the implant with an upper force limit of 4000N. Maximum force reached and load to failure, defined as movement of the implant by 5mm, were recorded. Four implants were used per group to give a total of 48 tests between the two groups.

Results: The X-Bolt® demonstrated a superior average maximum total load push-out force compared to the DHS group for all of the TAD configurations tested. The maximum force reached in the X-Bolt® group was significantly higher than that in the DHS group at a TAD of 10mm (X-Bolt® 3299.25N vs. DHS 2843.75N, P<0.029) and 30mm (X-Bolt® 2908.25N vs. DHS 2030N, P<0.029). The X-Bolt® also had a higher load to failure than the DHS group at all of the TAD values tested.

Conclusions: The X-Bolt® implant gave superior performance compared to the standard DHS, as reflected by a greater push-out force in an osteoporotic Sawbones® model.

Download full-text PDF

Source

Publication Analysis

Top Keywords

dynamic hip
8
hip screw
8
tip-apex distances
8
femoral head
8
tad 10mm
8
maximum force
8
force reached
8
dhs group
8
group tad
8
x-bolt®
5

Similar Publications

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.

View Article and Find Full Text PDF

Background: We aimed to synthesize the kinematics and kinetics during landing and walking/running tasks of ankle copers compared with patients with chronic ankle instability and controls.

Methods: We systematically searched PubMed, CINAHL, SPORTDiscus, and Web of Science. Tri-planar lower extremity biomechanics (joint angle and moment at maximum and initial contact, and joint displacement) were synthesized using standard mean difference and 95 % confidence intervals.

View Article and Find Full Text PDF

A new 3D full-body scanner analyzing the sagittal and coronal balance of the adult spine: a preliminary prospective observational study.

Acta Neurochir (Wien)

January 2025

Department of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.

Background: The degenerative spondylosis can cause the difficulty in maintaining sagittal and coronal alignment of spine, and X-ray parameters are the gold standard to analyze the malalignment. This study aimed to develop a new 3D full body scanner to analyze the spinal balance and compare it to X-ray parameters.

Methods: Ninety-seven adult participants who suffer degenerative spondylosis underwent 3D full body scanning, whole spine X-rays, clinical questionnaires and body composition analyses.

View Article and Find Full Text PDF

Background: Knee valgus loading is thought to be an important contributor to noncontact anterior cruciate ligament (ACL) injuries, but the effects of training programs focusing on decreasing knee valgus loading on lower extremity biomechanics with respect to ACL injury risk remain unclear. Thus, this study aimed to examine the effect of strength training designed to strengthen the medial thigh muscles on lower extremity joint kinematics, kinetics and muscle activity during single-leg landing.

Methods: A total of 35 healthy participants randomly conducted either exercises targeting medial thigh muscles (intervention group) or exercises that did not target specific lower extremity muscles (control group).

View Article and Find Full Text PDF

Predicting lower body joint moments and electromyography signals using ground reaction forces during walking and running: An artificial neural network approach.

Gait Posture

January 2025

Department of Biomechanics and Center for Research in Human Movement Variability, University of Nebraska at Omaha, Omaha, NE 68182, USA; Department of Surgery and Research Service, Nebraska-Western Iowa Veterans Affairs Medical Center, Omaha, NE 68105, USA. Electronic address:

Background: This study leverages Artificial Neural Networks (ANNs) to predict lower limb joint moments and electromyography (EMG) signals from Ground Reaction Forces (GRF), providing a novel perspective on human gait analysis. This approach aims to enhance the accessibility and affordability of biomechanical assessments using GRF data, thus eliminating the need for costly motion capture systems.

Research Question: Can ANNs use GRF data to accurately predict joint moments in the lower limbs and EMG signals?

Methods: We employed ANNs to analyze GRF data and to use them to predict joint moments (363-trials; 4-datasets) and EMG signals (63-trials; 2-datasets).

View Article and Find Full Text PDF