This study aimed to compare force, velocity, and power output collected under different loads, as well as the force-velocity (F-V) relationship between three measurement methods. Thirteen male judokas were tested under four loading conditions (20, 40, 60, and 80 kg) in the countermovement jump (CMJ) exercise, while mechanical output data were collected by three measurement methods: the Samozino's method (SAM), a force platform (FP), and a linear velocity transducer (LVT). The variables of the linear F-V relationship (maximum force [F0], maximum velocity [V0], F-V slope, and maximum power [P0]) were determined. The results revealed that (1) the LVT overestimated the mechanical output as compared to the SAM and FP methods, especially under light loading conditions, (2) the SAM provided the lowest magnitude for all mechanical output, (3) the F-V relationships were highly linear either for the SAM (r = 0.99), FP (r = 0.97), and LVT (r = 0.96) methods, (4) the F-V slope obtained by the LVT differed with respect to the other methods due to a larger V0 (5.28 ± 1.48 m·s-1) compared to the SAM (2.98 ± 0.64 m·s-1) and FP (3.06 ± 0.42 m·s-1), and (5) the methods were significantly correlated for F0 and P0, but not for V0 or F-V slope. These results only support the accuracy of the SAM and FP to determine the F-V relationship during the CMJ exercise. The very large correlations of the SAM and LVT methods with respect to the FP (presumed gold-standard) for the mean values of force, velocity and power support their concurrent validity for the assessment of mechanical output under individual loads.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714365PMC
http://dx.doi.org/10.2478/hukin-2018-0085DOI Listing

Publication Analysis

Top Keywords

mechanical output
16
measurement methods
12
f-v relationship
12
f-v slope
12
countermovement jump
8
methods
8
force velocity
8
velocity power
8
three measurement
8
loading conditions
8

Similar Publications

Lightweight 3D-printed chitosan/MXene aerogels for advanced electromagnetic shielding, energy harvesting, and thermal management.

Carbohydr Polym

March 2025

Microcellular Plastics Manufacturing Laboratory, Department of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Road, Toronto, Ontario M5S 3G8, Canada. Electronic address:

This study focuses on the fabrication of 3D-printed chitosan/TiCT-MXene aerogels with varying MXene concentrations (1, 2, 5, and 10 wt%) using the direct ink writing (DIW) method. The inks were freeze-dried to form aerogels, and FTIR and XRD analyses confirmed interactions between chitosan and MXene molecules, leading to increased spacing between MXene nanosheets. Rheological testing showed improved shear-thinning behavior, enhancing printability.

View Article and Find Full Text PDF

Effects of Variable Ventilation on Gas Exchange in an Experimental Model of Capnoperitoneum: A Randomized Crossover Study.

Anesth Analg

January 2025

From the Unit for Anaesthesiological Investigations, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland.

Background: The rapid advancement of minimally invasive surgical techniques has made laparoscopy a preferred alternative because it reduces postoperative complications. However, inflating the peritoneum with CO2 causes a cranial shift of the diaphragm decreasing lung volume and impairing gas exchange. Additionally, CO2 absorption increases blood CO2 levels, further complicating mechanical ventilation when the lung function is already compromised.

View Article and Find Full Text PDF

Introduction: The understanding of the interaction of closed-loop control of ventilation and oxygenation, specifically fraction of inspired oxygen (FiO2) and positive end-expiratory pressure (PEEP), and fluid resuscitation after burn injury and acute lung injury from smoke inhalation is limited. We compared the effectiveness of FiO2, PEEP, and ventilation adjusted automatically using adaptive support ventilation (ASV) and decision support fluid resuscitation based on urine output in a clinically relevant conscious ovine model of lung injury secondary to combined smoke inhalation and major burn injury.

Methods: Sheep were subjected to burn and smoke inhalation injury under deep anesthesia and analgesia.

View Article and Find Full Text PDF

Piezoelectric Vitamin-Based Self-Assemblies for Energy Generation.

Adv Mater

January 2025

Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, 400044, China.

Structural diversity of biomolecules leads to various supramolecular organizations and asymmetric architectures of self-assemblies with significant piezoelectric response. However, the piezoelectricity of biomolecular self-assemblies has not been fully explored and the relationship between supramolecular structures and piezoelectricity remains poorly understood, which hinders the development of piezoelectric biomaterials. Herein, for the first time, the piezoelectricity of vitamin-based self-assemblies for power generation is systematically explored.

View Article and Find Full Text PDF

RNA plays a crucial role not only in information transfer as messenger RNA during gene expression but also in various biological functions as non-coding RNAs. Understanding mechanical mechanisms of function needs tertiary structure information; however, experimental determination of three-dimensional RNA structures is costly and time-consuming, leading to a substantial gap between RNA sequence and structural data. To address this challenge, we developed NuFold, a novel computational approach that leverages state-of-the-art deep learning architecture to accurately predict RNA tertiary structures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?