Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Left atrial (LA) size is an established predictor of recurrence after catheter ablation for paroxysmal atrial fibrillation (PAF). We investigated the impact of baseline LA function on recurrence after PAF ablation and compared the predictive values of LA function with those of LA size.
Methods: We retrospectively investigated 292 consecutive patients who underwent PAF ablation (median follow-up: 3.0 years). All patients had their preoperative LA volume (LAV) assessed using cardiac computed tomography under sinus rhythm. We used LA emptying fraction (LAEF) as an indicator of LA function and assessed the association between baseline LAEF and recurrence after initial ablation using a multivariate Cox hazard model. Then, we performed receiver operating characteristic analysis for predicting recurrence after single and multiple procedures and compared the c-statistics of LAEF and indexed maximum and minimum LAV (LAVI and LAVI) RESULTS: In a multivariate Cox hazard model, LAEF was strongly associated with recurrence after a single procedure [hazard ratio (HR): 0.968, 95% confidence interval (CI): 0.951-0.985, p < 0.001]. In the receiver operating characteristic analysis for predicting recurrence, the predictive accuracy of LAEF was mild after a single procedure [area under the curve (AUC): 0.666, p < 0.001] and moderate after multiple procedures (AUC: 0.701, p < 0.001). The c-statistic of LAEF was significantly higher than those of LAVI and LAVI after a single procedure (p < 0.05, for both). After adjustment for factors related to reduced LAEF (increased serum brain natriuretic peptide, age, LA diameter, and reduced left ventricular ejection fraction), it was still associated with recurrence (HR: 0.964, 95% CI: 0.946-0.982, p < 0.001).
Conclusions: LAEF was associated with recurrence after PAF ablation. LA function is a more useful predictor than LA size.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jjcc.2019.08.014 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!