Patient Safety Analysis in Radiation Burden of Head Computed Tomography Imaging in 1185 Neurosurgical Inpatients.

World Neurosurg

Department of Neurosurgery, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Radiation Safety, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Physics & Biology in Medicine Graduate Program, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Radiology, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Radiological Sciences-Section of Neuroradiology, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Head and Neck Surgery, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Department of Radiation Oncology, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Jonsson Comprehensive Cancer Center, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Los Angeles Biomedical Research Institute, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA; Harbor-UCLA Medical Center, David Geffen School of Medicine of the University of California, Los Angeles (UCLA), Los Angeles, California, USA. Electronic address:

Published: January 2020

Objective: We performed a retrospective analysis in a cohort of 1185 patients at our institution who were identified as undergoing ≥1 head computed tomography (CT) examinations during their inpatient stay on the neurosurgery service, to quantify the number, type, and associated radiation burden of head CT procedures performed by the neurosurgery service.

Methods: CT procedure records and radiology reports were obtained via database search and directly validated against records retrieved from manual chart review. Next, dosimetry data from the head CT procedures were extracted via automated text mining of electronic radiology reports.

Results: Among 4510 identified adult head CT procedures, 88% were standard head CT examinations. A total of 3.65 ± 3.60 head CT scans were performed during an average adult admission. The most common primary diagnoses were neoplasms, trauma, and other hemorrhage. The median cumulative effective dose per admission was 5.66 mSv (range, 1.06-84.5 mSv; mean, 8.56 ± 8.95 mSv). The median cumulative effective dose per patient was 6.4 mSv (range, 1.1-127 mSv; mean, 9.26 ± 10.0 mSv).

Conclusions: The median cumulative radiation burden from head CT imaging in our cohort equates approximately to a single chest CT scan, well within accepted limits for safe CT imaging in adults. Refined methods are needed to characterize the safety profile of the few pediatric patients identified in our study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2019.09.004DOI Listing

Publication Analysis

Top Keywords

radiation burden
12
burden head
12
head procedures
12
median cumulative
12
head
8
head computed
8
computed tomography
8
cumulative effective
8
effective dose
8
msv range
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!