The emission of Cherenkov photons from human and animal tissue can be observed during clinical x-ray or particle beam irradiation. However, imaging this weak emission with the necessary single-photon sensitivity in the clinical room is challenging because of milliwatt-level ambient room lighting and the presence of stray high-energy radiation. In this Letter, we demonstrate, to the best of our knowledge, the first Cherenkov imaging with a time-gated quanta image sensor employing a large single-photon avalanche diode (SPAD) array. Detecting single Cherenkov photons was possible with high photon avalanche gain, fast temporal gating, and moderately high ∼7% photon detection probability. Single-bit digitization and active SPAD quenching enabled stray x-ray noise suppression and photon-noise-limited imaging in a clinical environment. This type of imaging allows the knowledge of location, shape, and surface dose of the therapeutic beam radiotherapy with the stability of solid state-based detection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7181332PMC
http://dx.doi.org/10.1364/OL.44.004546DOI Listing

Publication Analysis

Top Keywords

quanta image
8
image sensor
8
cherenkov photons
8
imaging
5
imaging cherenkov
4
cherenkov photon
4
photon emissions
4
emissions radiotherapy
4
radiotherapy geiger-mode
4
geiger-mode gated
4

Similar Publications

Acne and acne sequelae can have an important impact on patients' quality of life, affecting interpersonal relationships and social functioning. Acne-induced scars (AIS) and acne-induced macular hyperpigmentation (AIH), in particular, are a major concern for patients with acne, as their management is challenging and often unsatisfactory. Retinoids are considered the mainstay of acne treatment because of their action on multiple pathogenetic factors, and there is increasing evidence that they can also improve AIS and AIH.

View Article and Find Full Text PDF

Background: Photon counting computed tomography (PCCT) employs direct and spectrally resolved counting of individual x-ray quanta, enhancing image quality compared to the standard energy-integrating CT (EICT).

Purpose: To evaluate the quantitative improvements in CT image quality metrics by comparing the first medical PCCT with a state-of-the-art EICT.

Methods: The PCCT versus EICT noise improvement ratio R was derived from the quantum statistics of the measurement process and measured across the clinical x-ray flux range for both systems.

View Article and Find Full Text PDF

Autofluorescence is a remarkable property of human skin. It can be excited by UV and observed in the dark using special detection systems. The method of fluorescence photography (FP) is an effective non-invasive tool for skin assessment.

View Article and Find Full Text PDF

Morphological changes of cerebral gray matter in spinocerebellar ataxia type 3 using fractal dimension analysis.

Prog Brain Res

October 2024

Institute of Biophotonics, National Yang Ming Chiao Tung University, Taipei, Taiwan; Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan; Brain Research Center, National Yang Ming Chiao Tung University, Taipei, Taiwan. Electronic address:

Spinocerebellar ataxia type 3 (SCA3), or Machado-Joseph disease, presents as a cerebellar cognitive affective syndrome (CCAS) and represents the predominant SCA genotype in Taiwan. Beyond cerebellar involvement, SCA3 patients exhibit cerebral atrophy. While prior neurodegenerative disease studies relied on voxel-based morphometry (VBM) for brain atrophy assessment, its qualitative nature limits individual and region-specific evaluations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!