Aim: This study aimed to evaluate the dosimetric impact of uncorrected yaw rotational error on both target coverage and OAR dose metrics in this patient population.
Background: Rotational set up errors can be difficult to correct in lung VMAT SABR treatments, and may lead to a change in planned dose distributions.
Materials And Methods: We retrospectively applied systematic yaw rotational errors in 1° degree increments up to -5° and +5° degrees in 16 VMAT SABR plans. The impact on PTV and OARs (oesophagus, spinal canal, heart, airway, chest wall, brachial plexus, lung) was evaluated using a variety of dose metrics. Changes were assessed in relation to percentage deviation from approved planned dose at 0 degrees.
Results: Target coverage was largely unaffected with the largest mean and maximum percentage difference being 1.4% and 6% respectively to PTV D98% at +5 degrees yaw.Impact on OARs was varied. Minimal impact was observed in oesophagus, spinal canal, chest wall or lung dose metrics. Larger variations were observed in the heart, airway and brachial plexus. The largest mean and maximum percentage differences being 20.77% and 311% respectively at -5 degrees yaw to airway D0.1cc, however, the clinical impact was negligible as these variations were observed in metrics with minimal initial doses.
Conclusions: No clinically unacceptable changes to dose metrics were observed in this patient cohort but large percentage deviations from approved dose metrics in OARs were noted. OARs with associated PRV structures appear more robust to uncorrected rotational error.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6731354 | PMC |
http://dx.doi.org/10.1016/j.rpor.2019.07.010 | DOI Listing |
Clin Transl Radiat Oncol
March 2025
Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550, Japan.
Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.
Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.
Am J Psychiatry
January 2025
Nathan Kline Institute for Psychiatric Research, Orangeburg, NY (Stern, Collins, Bragdon, Eng, Recchia, Tobe, Iosifescu); Department of Psychiatry (Stern, Bragdon, Eng, Recchia, Iosifescu) and Neuroscience Institute (Stern, Iosifescu), New York University Langone Medical Center, New York; Department of Psychiatry, University of Miami Medical School, Miami (Coffey); Department of Psychiatry, Icahn School of Medicine at Mount Sinai, New York (Leibu, Murrough); Center for the Developing Brain, Child Mind Institute, New York (Tobe); Department of Psychiatry, Brigham and Women's Hospital, Boston (Burdick); Harvard Medical School, Boston (Burdick); Department of Psychiatry, Baylor College of Medicine, Houston (Goodman).
Objective: Sensory phenomena (SP) are aversive sensations driving repetitive behaviors in obsessive-compulsive disorder (OCD) and Tourette's disorder that are not well addressed by standard treatments. SP are related to the functioning of an interoceptive-sensorimotor circuit that may be modulated by the 5-HT receptor antagonist ondansetron. The present study employed an experimental medicine approach to test the effects of 4 weeks of high-dose ondansetron compared to placebo on SP severity and brain connectivity in a cohort of individuals with OCD and/or Tourette's disorder.
View Article and Find Full Text PDFNeurogastroenterol Motil
January 2025
Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA.
Background: The carbon-13 spirulina gastric emptying breath test (GEBT) is approved to identify delayed, but not accelerated, gastric emptying (GE). We compared the utility of the GEBT to scintigraphy for diagnosing abnormal GE in patients with diabetes mellitus.
Methods: Twenty-eight patients with diabetes ate a 230-kcal test meal labeled with technetium 99 m and C-spirulina, after which 10 scintigraphic images and breath samples (baseline, 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 min) were collected on 2 occasions 1 week apart.
J Appl Clin Med Phys
January 2025
Department of Radiation Medicine and Applied Sciences, UC San Diego Health, La Jolla, California, USA.
Purpose: Daily online adaptive radiotherapy (ART) improves dose metrics for gynecological cancer patients, but the on-treatment process is resource-intensive requiring longer appointments and additional time from the entire adaptive team. To optimize resource allocation, we propose a model to identify high-priority patients.
Methods: For 49 retrospective cervical and endometrial cancer patients, we calculated two initial plans: the treated standard-of-care (Initial) and a reduced margin initial plan (Initial) for adapting with the Ethos treatment planning system.
Cureus
December 2024
General Medicine, Rehman Medical Institue, Peshawar, PAK.
This systematic review evaluates the success rates of dental implants in patients with type 2 diabetes mellitus, focusing on outcomes such as implant survival, marginal bone loss, and peri-implant biomarkers. A comprehensive literature search was conducted across multiple databases, including PubMed, Cochrane, Embase, Scopus, and Web of Science, to identify relevant systematic reviews and meta-analyses. Four studies were included, encompassing diverse populations and interventions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!