Major cardiovascular diseases (CVDs) are associated with (regional) dysfunction of the left ventricle. Despite the 3-D nature of the heart and its dynamics, the assessment of myocardial function is still largely based on 2-D ultrasound imaging, thereby making diagnosis heavily susceptible to the operator's expertise. Unfortunately, to date, 3-D echocardiography cannot provide adequate spatiotemporal resolution in real-time. Hence, tri-plane imaging has been introduced as a compromise between 2-D and true volumetric ultrasound imaging. However, tri-plane imaging typically requires high-end ultrasound systems equipped with fully populated matrix array probes embedded with expensive and little flexible electronics for two-stage beamforming. This article presents an advanced ultrasound system for real-time, high frame rate (HFR), and tri-plane echocardiography based on low element count sparse arrays, i.e., the so-called spiral arrays. The system was simulated, experimentally validated, and implemented for real-time operation on the ULA-OP 256 system. Five different array configurations were tested together with four different scan sequences, including multi-line and planar diverging wave transmission. In particular, the former can be exploited to achieve, in tri-plane imaging, the same temporal resolution currently used in clinical 2-D echocardiography, at the expenses of contrast (-3.5 dB) and signal-to-noise ratio (SNR) (-8.7 dB). On the other hand, the transmission of planar diverging waves boosts the frame rate up to 250 Hz, but further compromises contrast (-10.5 dB), SNR (-9.7 dB), and lateral resolution (+46%). In conclusion, despite an unavoidable loss in image quality and sensitivity due to the limited number of elements, HFR tri-plane imaging with spiral arrays is shown to be feasible in real-time and may enable real-time functional analysis of all left ventricular segments of the heart.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2019.2940289DOI Listing

Publication Analysis

Top Keywords

tri-plane imaging
16
spiral arrays
12
tri-plane echocardiography
8
ultrasound imaging
8
frame rate
8
hfr tri-plane
8
planar diverging
8
real-time
6
imaging
6
tri-plane
5

Similar Publications

Aims: Apical foreshortening leads to an underestimation of left ventricular (LV) volumes and an overestimation of LV ejection fraction and global longitudinal strain. Real-time guiding using deep learning (DL) during echocardiography to reduce foreshortening could improve standardization and reduce variability. We aimed to study the effect of real-time DL guiding during echocardiography on measures of LV foreshortening and inter-observer variability.

View Article and Find Full Text PDF

Capitalizing on the recent advances in image generation models, existing controllable face image synthesis methods are able to generate high-fidelity images with some levels of controllability, e.g., controlling the shapes, expressions, textures, and poses of the generated face images.

View Article and Find Full Text PDF

Facial editing is to manipulate the facial attributes of a given face image. Nowadays, with the development of generative models, users can easily generate 2D and 3D facial images with high fidelity and 3D-aware consistency. However, existing works are incapable of delivering a continuous and fine-grained editing mode (e.

View Article and Find Full Text PDF

Background: Fibular hemimelia (FH) represents the most common deficiency of the long bones and is associated with multiple deformities. Reconstructive treatment with external fixators in FH restores normal lower extremity alignment and length with plantigrade feet for a balanced and effective gait. The aim of this study is to evaluate the outcomes of lower limb lengthening and simultaneous tri-plane deformity correction with a computer-assisted hexagonal external fixator in children with FH.

View Article and Find Full Text PDF
Article Synopsis
  • First metatarsal phalangeal (MTP) joint arthrodesis is a common surgical procedure used to relieve pain from arthritis and correct hallux valgus deformity.
  • A survey of 60 patients revealed that a high percentage (96.7%) could walk without pain, and nearly all (98.3%) walked at a normal pace after the surgery.
  • Patients quickly resumed activities, returning to a fracture boot in about 4.1 days and full activity in roughly 13.3 weeks, with an overall low complication rate and effective deformity correction.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!