Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We recently conducted an open-label phase I/II study to evaluate the efficacy and safety of preoperative and chronic treatment with metyrosine (an inhibitor of catecholamine synthesis) in pheochromocytoma/paraganglioma (PPGL) in Japan. We compared creatinine-corrected metanephrine fractions in spot urine and 24-hour urine samples (the current standard for the screening and diagnosis of PPGLs) from 16 patients to assess the therapeutic effect of metyrosine. Percent changes from baseline in urinary metanephrine (uMN) or normetanephrine (uNMN) were compared between spot and 24-hour urine samples. Mean percent changes in uMN or uNMN in spot and 24-hour urine were -26.36% and -29.27%, respectively. The difference in the percent change from baseline between uMN or uNMN in spot and 24-hour urine was small (-2.90%). The correlation coefficient was 0.87 for percent changes from baseline between uMN or uNMN measured in spot and 24-hour urine. The area under the receiver operator characteristic (ROC) curve of uMN or uNMN measured in spot urine vs. 24-hour urine (reference standard) to assess the efficacy of metyrosine treatment was 0.93. Correlations and ROCs between 24-hour urinary vanillylmandelic acid, adrenaline, and noradrenaline and 24-hour uMN or uNMN were similar to those between spot uMN or uNMN and 24-hour uMN or uNMN. No large difference was observed between spot and 24-hour urine for the assessment of metyrosine treatment by quantifying uMN or uNMN in Japanese patients with PPGLs. These results suggest that spot urine samples may be useful in assessing the therapeutic effect of metyrosine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1507/endocrj.EJ19-0125 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!