Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine the long-term repeatability of optical coherence tomography angiography (OCTA) parameters in normal eyes.
Methods: We prospectively enrolled 104 normal eyes. Participants were divided into three groups based on differences in the signal strength (SS) of OCTA scans obtained at two visits at least 6 months apart: group 1, SS difference = 2; group 2, 1; group 3, 0. We measured a foveal centred scan area of 3 × 3 mm pattern. All measurements were performed twice at 5-min intervals at the initial visit. The second measurements were performed at least 6 months later.
Results: In short-term vessel density (VD) repeatability, the coefficient of variation (CV) ranged from 3.89% to 8.10% and the intraclass correlation coefficient (ICC) ranged from 0.785 to 0.941. In terms of long-term repeatability, the CV was 5.39-12.62% and the ICC was 0.598-0.867. In group 1, the ICCs of the inner and full VDs were 0.194 and 0.221, respectively. In groups 2 and 3, the ICCs of the inner and full VDs were 0.611 and 0.603, and 0.763 and 0.765, respectively. The central VDs of all groups had high CV besides high ICC.
Conclusions: Optical coherence tomography angiography parameters showed good short-term and reasonable long-term repeatability in normal individuals. The differences in SSs between measurements affected such repeatability, so physicians should query the reliability of OCTA parameters when the differences in SS are 2 or more even when the SS is high.