A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of bicarbonate values from venous blood gas and chemistry panels measured at the time of diagnosis and resolution of diabetes ketoacidosis. | LitMetric

Comparison of bicarbonate values from venous blood gas and chemistry panels measured at the time of diagnosis and resolution of diabetes ketoacidosis.

J Clin Transl Endocrinol

Section of Endocrinology, Diabetes and Nutrition, Boston University School of Medicine, Boston University Medical Center, 720 Harrison Ave, Doctors Office Building, #8100, Boston, MA 02118, United States.

Published: December 2019

Objective: To determine if bicarbonate values from venous blood gas (VBG) and plasma chemistry samples provided agreement in determining the bicarbonate criteria for the diagnosis and/or resolution of diabetic ketoacidosis (DKA).

Methods: A retrospective chart review of data from patients admitted to a tertiary care hospital with a diagnosis of DKA over a four year period was performed. Paired bicarbonate values from a VBG and chemistry panel, if drawn within 60 minutes of each other, were compared.

Results: At the time of diagnosis of DKA, 197 paired bicarbonate values were available for analysis with the mean difference between the two methods of testing of 2.5 mmol/L. 16 of the 197 (8%) paired values were discordant in meeting criteria for diagnosis of DKA. At the time of resolution of DKA, 83 paired bicarbonate samples were compared. The mean difference was 2.3 mmol/L. 20 of the 83 (24%) paired bicarbonate values showed discordance with regards to meeting the bicarbonate criteria for resolution of DKA.

Conclusion: Discordance between bicarbonate results from different analysis methods may lead to different determinations as to whether or not a patient meets the biochemical definition for diagnosis and resolution of DKA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6727012PMC
http://dx.doi.org/10.1016/j.jcte.2019.100205DOI Listing

Publication Analysis

Top Keywords

bicarbonate values
20
paired bicarbonate
16
diagnosis dka
12
values venous
8
venous blood
8
blood gas
8
time diagnosis
8
diagnosis resolution
8
bicarbonate
8
bicarbonate criteria
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!