The introduction of a lower cost alternative to a film commonly used for megavoltage radiation therapy port films led to a comparison of two films (Kodak X-TL and X-OMAT G) in four metal screen cassette configurations. In addition to determination of H-D curves and point spread functions, images of humanoid phantom sections were obtained and evaluated for clinical "usefulness." The X-OMAT G film-screen combinations compared favorably with the X-TL film combinations with respect to the H-D Curves and point spread functions but there was a slight preference for X-TL film. There were no differences noted whether the film was used in the standard "ready pack" or naked in the cassettes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0958-3947(88)90039-8 | DOI Listing |
Asian Pac J Cancer Prev
December 2024
Department of Physics, Lovely Professional University, Phagwara, India.
Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.
Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.
JCO Glob Oncol
December 2024
Department of Radiotherapy, Erasmus MC Cancer Institute, Rotterdam, the Netherlands.
Purpose: Moderate hypofractionation (MHF) offers logistical and financial advantages, and has become standard in Western countries but not yet in Africa. This study assessed GI and genitourinary (GU) acute toxicity in Rwandan men undergoing MHF (20 × 3 Gy) treatment.
Materials And Methods: Since 2021, patients with prostate cancer at the Rwanda Cancer Centre have been informed about the study on MHF treatment and could participate by signing an informed consent.
J Med Radiat Sci
December 2024
Radiation Oncology Department, Sir Charles Gairdner Hospital, Perth, Western Australia, Australia.
Over the past decade, our institution delivered conventional total body irradiation (TBI) using Elekta's Monaco treatment planning system (TPS) with an extended SSD field arrangement and 18 megavoltage (MV) energy lateral fields. In 2020, there was a transition to the Eclipse™ treatment planning system and Truebeam® linear accelerators with 6 MV and 10 MV energies. These changes meant that essential components of the existing technique were unavailable for clinical use and a new approach to the institution technique was required to ensure continuation of service.
View Article and Find Full Text PDFStrahlenther Onkol
December 2024
Department of Radiation Oncology, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, 07061, Seoul, Korea (Republic of).
Purpose: This study aimed to assess the impact of different energy levels on the effectiveness of low-dose radiotherapy (LDRT) for treating painful degenerative musculoskeletal diseases, as comparative efficacy data are currently lacking.
Methods: A systematic review was conducted in PubMed, Embase, and the Cochrane Library databases to identify studies with response information on the energy used (kilovoltage [kV] vs. megavoltage [MV]).
Med Phys
November 2024
Image X Institute, The University of Syndey, Sydney, Australia.