Introduction: There are no data presenting a serial assessment of vein graft healing after bioresorbable vascular scaffold (BVS) implantation at long-term follow-up.
Aim: To describe ABSORB BVS healing in vein grafts by optical coherence tomography (OCT) and high-definition intravascular imaging (HD-IVUS) at long-term follow-up.Material and methods: The study group consisted of 6 patients. The first patient had serial OCT assessment of BVS implanted in the saphenous vein grafts (SVG) at baseline and at 3-, 6-, 18-month follow-up and the second patient had OCT assessment of BVS implanted in the SVG at baseline and 24-, 48-month follow-up. The second and the third patients had OCT and HD-IVUS imaging at baseline and 48-month follow-up. The last 3 patients had OCT imaging of BVS implanted in the native coronary artery at 48-month follow-up.
Results: There were no differences in neointimal hyperplasia after BVS implantation between each time point. However, complete scaffold coverage was observed only 48 months after implantation. Out of 202 analyzed scaffold struts, there were 67 (33%) black boxes detectable at 48-month follow-up. HD-IVUS presented plaque burden up to 67% at the segment of BVS implantation at 48-months follow-up. There was a difference in neointimal hyperplasia thickness (1.27 (0.953-1.696) vs. 0.757 (0.633-0.848), < 0.001) between a native coronary artery and BVS scaffolds at 48-month follow-up.
Conclusions: Bioresorbable vascular scaffold implanted in SVG characterized moderate neointimal hyperplasia as excessive as compared to native coronary arteries at long-term follow-up. The complete scaffold coverage was observed only 48 months after implantation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6727228 | PMC |
http://dx.doi.org/10.5114/aic.2019.86010 | DOI Listing |
Regen Biomater
December 2024
Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, Sichuan 610031, China.
Modification of polylactic acid (PLA) is a promising strategy for the next generation of bioresorbable vascular stent biomaterials. With this focus, FeMOFs nanoparticles was incorporated in PLA, and then post loading of carbon monoxide (CO) was performed by pressurization. It showed FeMOFs incorporation increased hydrophilicity of the surface and CO loading, and CO release was sustained at least for 3 days.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
College of Materials Science and Engineering, Wuhan Textile University, Wuhan 430070, China.
Artificial blood vessels made from polyurethane (PU) have been researched for many years but are not yet in clinical use. The main reason was that the PU materials are prone to degradation after contact with blood and will also cause inflammation after long-term implantation. At present, PU has made progress in biostability and biocompatibility, respectively.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Department of Applied Mathematics, Materials Science and Engineering and Electronic Technology, Escuela Superior de Ciencias Experimentales y Tecnología (ESCET), Universidad Rey Juan Carlos, C/Tulipán s/n, 28933 Móstoles, Spain.
This review explores the advancements in additive manufacturing (AM) of biodegradable iron (Fe) and zinc (Zn) alloys, focusing on their potential for medical implants, particularly in vascular and bone applications. Fe alloys are noted for their superior mechanical properties and biocompatibility but exhibit a slow corrosion rate, limiting their biodegradability. Strategies such as alloying with manganese (Mn) and optimizing microstructure via laser powder bed fusion (LPBF) have been employed to increase Fe's corrosion rate and mechanical performance.
View Article and Find Full Text PDFPhys Eng Sci Med
January 2025
Faculty of Engineering, Department of Biomedical Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.
J Mech Behav Biomed Mater
December 2024
Department of Bionanosystem Engineering, Graduate School, Jeonbuk National University, Jeonju 54896, Republic of Korea; Department of Bionanotechnology and Bioconvergence Engineering, Graduate School, Jeonbuk National University, Jeonju 54896, Republic of Korea; Department of Mechanical Design Engineering, Graduate School, Jeonbuk National University, Jeonju 54896, Republic of Korea; Advanced Mechanical Components Design & Research Center, Jeonbuk National University, Jeonju 54896, Republic of Korea; Innovative Mechanobio Active Materials Based Medical Device Demonstration Center, Jeonbuk National University, Jeonju 54896, Republic of Korea. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!