Inorganic scintillation detectors for Ir brachytherapy.

Phys Med Biol

Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America.

Published: November 2019

Many brachytherapy (BT) errors could be detected with real-time in vivo dosimetry technology. Inorganic scintillation detectors (ISDs) have demonstrated promising capabilities for BT, because some ISD materials can generate scintillation signals large enough that (a) the background signal emitted in the fiber-optic cable (stem signal) is insignificant, and (b) small detector volumes can be used to avoid volume averaging effects in steep dose gradients near BT sources. We investigated the characteristics of five ISD materials to identify one that is appropriate for BT. ISDs consisting of a 0.26 to 1.0 mm volume of ruby (AlO:Cr), a mixture of YO:Eu and YVO:Eu, ZnSe:O, or CsI:Tl coupled to a fiber-optic cable were irradiated in a water-equivalent phantom using a high-dose-rate Ir BT source. Detectors based on plastic scintillators BCF-12 and BCF-60 (0.8 mm volume) were used as a reference. Measurements demonstrated that the ruby, YO:Eu+YVO:Eu, ZnSe:O, and CsI:Tl ISDs emitted scintillation signals that were up to 19, 19, 250, and 880 times greater, respectively, than that of the BCF-12 detector. While the total signals of the plastic scintillation detectors were dominated by the stem signal for source positions 0.5 cm from the fiber-optic cable and  >3.5 cm from the scintillator volume, the stem signal for the ruby and YO:Eu+YVO:Eu ISDs were  <1% of the total signal for source positions  <3.4 and  <4.4 cm from the scintillator, respectively, and  <0.7% and  <0.5% for the ZnSe:O and CsI:Tl ISDs, respectively, for positions  ⩽8.0 cm. In contrast to the other ISDs, the YO:Eu+YVO:Eu ISD exhibited unstable scintillation and significant afterglow. All ISDs exhibited significant energy dependence, i.e. their dose response to distance-dependent Ir energy spectra differed significantly from the absorbed dose in water. Provided that energy dependence is accounted for, ZnSe:O ISDs are promising for use in error detection and patient safety monitoring during BT.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab421fDOI Listing

Publication Analysis

Top Keywords

scintillation detectors
12
fiber-optic cable
12
stem signal
12
inorganic scintillation
8
isd materials
8
scintillation signals
8
znseo csitl
8
ruby yoeu+yvoeu
8
detectors
4
detectors brachytherapy
4

Similar Publications

Improving timing resolution of BGO for TOF-PET: a comparative analysis with and without deep learning.

EJNMMI Phys

January 2025

Sherbrooke Molecular Imaging Center and Department of Nuclear Medicine and Radiobiology, Université de Sherbrooke, 12th Avenue N, Sherbrooke, J1H 5N4, Québec, Canada.

Background: The renewed interest in BGO scintillators for TOF-PET is driven by the improved Cherenkov photon detection with new blue-sensitive SiPMs. However, the slower scintillation light from BGO causes significant time walk with leading edge discrimination (LED), which degrades the coincidence time resolution (CTR). To address this, a time walk correction (TWC) can be done by using the rise time measured with a second threshold.

View Article and Find Full Text PDF

This study aims to enhance positron emission tomography (PET) imaging systems by developing a continuous depth-of-interaction (DOI) measurement technique using a single-ended readout. Our primary focus is on reducing the number of readout channels in the scintillation detectors while maintaining accurate DOI estimations, using a high-pass filter-based signal multiplexing technique combined with artificial neural networks (ANNs). Approach: Instead of reading out all 64 signals from an 8×8 silicon photomultiplier array for DOI estimation, the proposed method technique reduces the signals into just four channels by applying high-pass filters with different time constants.

View Article and Find Full Text PDF

(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber.

View Article and Find Full Text PDF

This paper presents the initial results of the synthesis of β-GaO luminescent ceramics via plasma gas-thermal spraying synthesis, where low-temperature plasma of an argon and nitrogen mixture was employed. A direct current electric arc generator of high-enthalpy plasma jet with a self-aligning arc length and an expanding channel of an output electrode served as a plasma source. The feedstock material consisted of a polydisperse powder of monocrystalline β-GaO with particle sizes ranging from 5 to 50 μm.

View Article and Find Full Text PDF

Design optimization of a 1-D array of stemless plastic scintillation detectors.

Med Phys

January 2025

Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.

Background: A stemless plastic scintillation detector (SPSD) is composed of an organic plastic scintillator coupled to an organic photodiode. Previous research has shown that SPSDs are ideally suited to challenging dosimetry measurements such as output factors and profiles in small fields. Lacking from the current literature is a systematic effort to optimize the performance of the photodiode component of the detector.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!