Objective: The hip and knee joints differ biomechanically in terms of contact stresses, fluid lubrication and wear patterns. These differences may be reflected in the synovial fluid (SF) composition of the two joints, but the nature of these differences remains unknown. The objective was to identify differences in osteoarthritic hip and knee SF metabolites using metabolic profiling with Nuclear Magnetic Resonance (NMR) spectroscopy.
Design: Twenty-four SF samples (12 hip, 12 knee) were collected from patients with end-stage osteoarthritis (ESOA) undergoing hip/knee arthroplasty. Samples were matched for age, gender, ethnicity and had similar medical comorbidities. NMR spectroscopy was used to analyse the metabolites present in each sample. Principal Component Analysis and Orthogonal Partial Least Squares Discriminant Analysis were undertaken to investigate metabolic differences between the groups. Metabolites were identified using 2D NMR spectra, statistical spectroscopy and by comparison to entries in published databases.
Results: There were significant differences in the metabolic profile between the groups. Four metabolites were found in significantly greater quantities in the knee group compared to the hip group (N-acetylated molecules, glycosaminoglycans, citrate and glutamine).
Conclusions: This is the first study to indicate differences in the metabolic profile of hip and knee SF in ESOA. The identified metabolites can broadly be grouped into those involved in collagen degradation, the tricarboxylic acid cycle and oxidative metabolism in diseased joints. These findings may represent a combination of intra and extra-articular factors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joca.2019.07.017 | DOI Listing |
Sports Biomech
January 2025
Department of Physical Education and Sport, University of Seville, Seville, Spain.
Despite the high incidence of knee injuries reported in non-professional sports, the implementation of specific training programmes aimed at mitigating the kinematic and kinetic factors associated with these injuries remains limited. To determine the effects of a tailored exercise programme on kinematic and kinetic variables during side-cutting activities. Fifty-seven physically active participants were randomised into control group (CG; n: 28) that received no intervention, and an experimental group (EG; n: 29), that performed an individualised exercise programme that included a combination of strength, neuromuscular, proprioceptive, eccentric training and whole-body vibration (WBV) exercises.
View Article and Find Full Text PDFSports Biomech
January 2025
Institute of Health and Sport Sciences, University of Tsukuba, Tsukuba, Japan.
It is well-known among swimmers and coaches that the swimming speed of the underwater dolphin kick (UDK) is higher than that of the underwater flutter kick (UFK). This study aimed to clarify the differences in swimming performance between the two kicking styles in terms of kinematics, kinetics and muscle activity. Eight male swimmers performed UDK and UFK in a water flume at same effort levels.
View Article and Find Full Text PDFSports Biomech
January 2025
Centre for Sport Studies, Rey Juan Carlos University, Madrid, Spain.
We analysed the long-term adaptations of resisted sprint training (RST) with combined loads on the performance and kinematics of the maximal velocity (MV). One team women's professional soccer players performed a six-week training programme with progressive sled loading from 20% to 80% of body mass. Pre-training, post-training and detraining measures were obtained for sprint times for 0-20 m, 20-30 m and 0-30 m, while step length (SL), step rate (SR), step velocity, trunk, hip, thigh, knee, shank ankle, foot and centre of mass (CoM) angles were digitised with an 18-point human model.
View Article and Find Full Text PDFCureus
December 2024
Orthopedic Surgery, Middlebrook Family Medicine, Middlebrook, USA.
The treatment for osteoarthritis (OA) often requires total joint arthroplasty (TJA) when less invasive approaches fail. The annual incidence of TJA is rising. Metal-on-metal (MoM) hip and knee implants were widely used for TJA in the past, but complications have led to their decline.
View Article and Find Full Text PDFJ Comp Eff Res
January 2025
Dartmouth-Hitchcock Medical Center, Department of Orthopaedics, Lebanon, NH, USA.
To examine contributions of a patient advisory board (PAB) to the design and conduct of The Pulmonary Embolism Prevention after Hip and Knee Replacement (PEPPER) Trial (NCT02810704) and compare perceptions of PAB members and researchers on the Trial. This evaluation of the PAB was conducted by Clinical Coordinating Center (CCC) members who first discussed PAB contributions, leading to the design of a semi-structured WebEx interview individually querying PAB members on their experience. Two study team members analyzed transcriptions of the interviews for common themes, which were discussed and affirmed at an in-person meeting with PAB members.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!