An optical design study of a bending-magnet beamline, based on multi-bend achromat storage ring lattices, at the High Energy Photon Source, to be built in Beijing, China, is described. The main purpose of the beamline design is to produce a micro-scale beam from a bending-magnet source with little flux loss through apertures. To maximize the flux of the focal spot, the synchrotron source will be 1:1 imaged to a virtual source by a toroidal mirror; a mirror pair will be used to collimate the virtual source into quasi-parallel light which will be refocused by a Kirkpatrick-Baez mirror pair. In the case presented here, a beamline for tender X-rays ranging from 2.1 keV to 7.8 keV, with a spot size of approximately 7 µm (H) × 6 µm (V) and flux up to 2 × 10 photons s, can be achieved for the purpose of X-ray absorption fine-structure (XAFS)-related experiments, such as scanning micro-XAFS and full-field nano-XAFS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S160057751900715X | DOI Listing |
Rev Sci Instrum
December 2024
Atomic and Molecular Physics Division, Bhabha Atomic Research Centre, Mumbai 400094, India.
We present a comprehensive overview of the commissioning process and initial results of a synchrotron beamline dedicated to atomic, molecular, and optical sciences at the BL-5 undulator port of the Indus-2 synchrotron facility, Raja Ramanna Center for Advanced Technology, Indore, India. The beamline delivers a photon flux of ∼1012 photons/s with high resolving power (∼10 000) over an energy range of 6-800 eV, making it suitable for high-resolution spectroscopy in atomic, molecular, and optical science. The energy tunability from vacuum ultraviolet to soft x-ray (6-800 eV) is achieved through a varied line spacing plane grating monochromator with four gratings: very low energy (VLEG), low energy (LEG), medium energy (MEG), and high energy (HEG).
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom.
We present here a newly developed software tool (called PGMweb) for computing and simulating the X-ray beam path through a plane grating monochromator (PGM), a key component in soft X-ray beamlines at modern synchrotron and free-electron laser facilities. A historical overview of the development of PGMs is presented, with special attention dedicated to the collimated PGM optical scheme found at several X-ray facilities worldwide. The analytical expressions that fully describe the geometry of a PGM are derived and have been implemented as functions in a Python library (pyplanemono).
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Institute Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin, Germany.
Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, Germany.
This paper introduces a novel slit-less wavelength-dispersive spectrometer design that incorporates a single-bounce monocapillary with the goal of positioning the sample directly on the Rowland circle, thereby eliminating the need for a traditional entrance slit. This configuration enhances photon throughput while preserving energy resolution, demonstrated in comparative measurements on boron nitride and different lithium nickel manganese cobalt oxide cathodes. A common alternative to an entrance slit for limiting the source size on the Rowland circle is a customized design of the beamline involving a focusing optics unit consisting of two Kirkpatrick-Baez mirrors close to the end station.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Polimero eta Material Aurreratuak: Fisika, Kimika eta Teknologia, Kimika Fakultatea, Euskal Herriko Unibertsitatea UPV/EHU, Donostia-San Sebastian 20018, Spain.
Data acquisition under cryogenic conditions allows one to avoid unwanted damage caused by beam irradiation. This is particularly important for the study of biological samples at hard X-ray, micro- or nano-probe beamlines, which focus synchrotron radiation to small beam sizes with extremely high flux densities. Sample preparation methods for cryopreserved specimens have been adapted from electron microscopy, and include the use of silicon nitride membranes as they are easy to handle and possess low X-ray absorption.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!