High-efficiency fast X-ray imaging detector development at SSRF.

J Synchrotron Radiat

Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, People's Republic of China.

Published: September 2019

Indirect X-ray imaging detectors consisting of scintillator screens, long-working-distance microscope lenses and scientific high-speed complementary metal-oxide semiconductor (CMOS) cameras are usually used to realize fast X-ray imaging with white-beam synchrotron radiation. However, the detector efficiency is limited by the coupling efficiency of the long-working-distance microscope lenses, which is only about 5%. A long-working-distance microscope lenses system with a large numerical aperture (NA) is designed to increase the coupling efficiency. It offers an NA of 0.5 at 8× magnification. The Mitutoyo long-working-distance microscope lenses system offers an NA of 0.21 at 7.5× magnification. Compared with the Mitutoyo system, the developed long-working-distance microscope lenses system offers about twice the NA and four times the coupling efficiency. In the indirect X-ray imaging detector, a 50 µm-thick LuAG:Ce scintillator matching with the NA, and a high-speed visible-light CMOS FastCAM SAZ Photron camera are used. Test results show that the detector realized fast X-ray imaging with a frame rate of 100000 frames s and fast X-ray microtomography with a temporal sampling rate up to 25 Hz (25 tomograms s).

Download full-text PDF

Source
http://dx.doi.org/10.1107/S1600577519010075DOI Listing

Publication Analysis

Top Keywords

x-ray imaging
20
long-working-distance microscope
20
microscope lenses
20
fast x-ray
16
coupling efficiency
12
lenses system
12
imaging detector
8
indirect x-ray
8
system offers
8
x-ray
6

Similar Publications

Purpose Of The Study: Open (incisional) biopsies have long been accepted as the gold standard in diagnosing bone and soft tissue tumors. However, the main disadvantage of this method is that it can lead to increased contamination, hematoma, infection, and pathological fracture. Compared to open biopsies, percutaneous core needle biopsies are less invasive, do not require hospitalization, have low costs and low complication rates, and there is no need for wound healing in cases that require radiotherapy.

View Article and Find Full Text PDF

Purpose Of The Study: Temporary hemiepiphyseodesis using figure-eight plates is currently one of the main surgical techniques to correct axial deformities of lower limbs in paediatric patients. Comprehensive analysis, correct indication and monitoring of treatment are the basic prerequisites for successful therapy. The aim of the study was to analyse parameters that could become an alternative to standard parameters used nowadays, namely the inserted screw angle (SA), and a new parameter - condylar ratio (CR).

View Article and Find Full Text PDF

Objective: Coronary artery disease (CAD) remains a significant global health burden, characterized by the narrowing or blockage of coronary arteries. Treatment decisions are often guided by angiography-based scoring systems, such as the Synergy Between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) and Gensini scores, although these require invasive procedures. This study explores the potential of electrocardiography (ECG) as a noninvasive diagnostic tool for predicting CAD severity, alongside traditional risk factors.

View Article and Find Full Text PDF

Objective: To evaluate the performance of Genki, a computer-aided detection (CADe) software, in detecting tuberculosis (TB) using chest radiography in a mobile TB screening program in Chennai, India.

Materials And Methods: Genki, an AI-based CADe software, was employed in four mobile diagnostic units in remote areas of Chennai, India for screening TB. Patients from remote areas of Chennai who visited the vans and registered in the screening program underwent chest radiography, and the acquired X-ray scans were analyzed using Genki, which provided an assessment of each scan as either "TB suggestive" or "TB not suggestive".

View Article and Find Full Text PDF

Background: Lumbar facet joint diseases can often lead to reduced work efficiency and increased medical costs. As a primary imaging tool in orthopedics, X-rays offer numerous advantages. However, there is no consensus on the classification of lumbar facet joints based on X-ray imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!