The European X-ray Free-Electron Laser (EuXFEL) delivers extremely intense (>10 photons pulse and up to 27000 pulses s), ultrashort (<100 fs) and transversely coherent X-ray radiation, at a repetition rate of up to 4.5 MHz. Its unique X-ray beam parameters enable novel and groundbreaking experiments in ultrafast photochemistry and material sciences at the Femtosecond X-ray Experiments (FXE) scientific instrument. This paper provides an overview of the currently implemented experimental baseline instrumentation and its performance during the commissioning phase, and a preview of planned improvements. FXE's versatile instrumentation combines the simultaneous application of forward X-ray scattering and X-ray spectroscopy techniques with femtosecond time resolution. These methods will eventually permit exploitation of wide-angle X-ray scattering studies and X-ray emission spectroscopy, along with X-ray absorption spectroscopy, including resonant inelastic X-ray scattering and X-ray Raman scattering. A suite of ultrafast optical lasers throughout the UV-visible and near-IR ranges (extending up to mid-IR in the near future) with pulse length down to 15 fs, synchronized to the X-ray source, serve to initiate dynamic changes in the sample. Time-delayed hard X-ray pulses in the 5-20 keV range are used to probe the ensuing dynamic processes using the suite of X-ray probe tools. FXE is equipped with a primary monochromator, a primary and secondary single-shot spectrometer, and a timing tool to correct the residual timing jitter between laser and X-ray pulses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6730617PMC
http://dx.doi.org/10.1107/S1600577519006647DOI Listing

Publication Analysis

Top Keywords

scientific instrument
4
instrument femtosecond
4
femtosecond x-ray
4
x-ray experiments
4
experiments fxe
4
fxe instrumentation
4
instrumentation baseline
4
baseline experimental
4
experimental capabilities
4
capabilities european
4

Similar Publications

In recent years, alternative enzymes with varied specificities have gained importance in MS-based bottom-up proteomics, offering orthogonal information about biological samples and advantages in certain applications. However, most mass spectrometric workflows are optimized for tryptic digests. This raises the questions of whether enzyme specificity impacts mass spectrometry and if current methods for nontryptic digests are suboptimal.

View Article and Find Full Text PDF

Overcoming the cognition-reality gap in robot-to-human handovers with anisotropic variable force guidance.

Comput Struct Biotechnol J

December 2024

The State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory of Remote Measurement and Control, School of Instrument Science and Engineering, Southeast University, Nanjing 210096, China.

Object handover is a fundamental task for collaborative robots, particularly service robots. In in-home assistance scenarios, individuals often face constraints due to their posture and declining physical functions, necessitating high demands on robots for flexible real-time control and intuitive interactions. During robot-to-human handovers, individuals are limited to making perceptual judgements based on the appearance of the object and the consistent behaviour of the robot.

View Article and Find Full Text PDF

Facial bone fractures are a common occurrence in trauma cases, particularly in India where road traffic accidents contribute significantly. Over the past few years, artificial intelligence (AI) has become a potent instrument to help medical professionals diagnose and treat facial fractures. This study aims to perform a bibliometric analysis, that is, a quantitative and qualitative analysis, of publications focusing on the role of AI in detecting facial bone fractures.

View Article and Find Full Text PDF

Background: Accurately assessing the activity of Crohn's disease (CD) is crucial for determining prognosis and guiding treatment strategies for CD patients.

Objective: This study aimed to develop and validate a nomogram for assessing CD activity.

Methods: The semi-automatic segmentation method and PyRadiomics software were employed to segment and extract radiomics features from the spectral CT enterography images of lesions in 107 CD patients.

View Article and Find Full Text PDF

MRPL24 drives breast cancer metastasis and stemness by targeting c-MYC, BRD4, and STAT3.

3 Biotech

February 2025

Key Laboratory of Optical Technology and Instrument for Medicine, Ministry of Education, University of Shanghai for Science and Technology, Shanghai, 200093 China.

Unlabelled: The study aims to investigate the clinicopathological significance of MRPL24 in human cancers, with a particular focus on breast cancer (BC). Comprehensive bioinformatics analyses were conducted using data from The Cancer Genome Atlas (TCGA) and various advanced database, including cBioPortal, UALCAN, TIMER, Prognoscan, TISIDB, KM Plotter, and The Human Protein Atlas, to provide a detailed evaluation of MRPL55's role in cancer. The findings were further validated through experimental studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!