Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Data on the prevalence and predictors for the development of pacing-dependency in patients with cardiovascular implantable electronic devices (CIEDs) are sparse.
Methods: Pacing-dependency defined as an absence of intrinsic rhythm of ≥ 30 bpm was determined in 802 consecutive patients with CIEDs who visited the documented pacemaker or implantable cardioverter- defibrillator outpatient clinic for routine follow-up.
Results: A total of 131 (16%) patients were found to be pacing-dependent 67 ± 70 months after CIED implant. Multivariate analysis revealed a significant association between pacing-dependency and the following clinical variables: second or third-degree atrioventricular (AV) block at implant (OR = 19.9; 95% CI: 10.9-38.5, p < 0.01), atrial fibrillation at implant (OR = 2.15; 95% CI: 1.16-4.05, p = 0.02), left ventricular ejection fraction (LVEF) ≤ 30% (OR = 2.06; 95% CI: 1.03-4.15, p = 0.04), B-type natriuretic peptide (BNP) > 150 pg/mL (OR = 2.12; 95% CI: 1.16-3.97, p = 0.02), chronic kidney disease (OR = 1.86; 95% CI: 1.08-3.26, p = 0.03), and follow-up duration after implantation > 5 years (OR = 3.29; 95% CI: 1.96-5.64, p < 0.01). None of the remaining clinical variables including age, gender, diabetes mellitus, underlying heart disease, prior cardiac surgery or medication during follow-up including betablockers and amiodarone predicted pacing-dependency.
Conclusions: Pacing-dependency is associated with second or third-degree AV-block at implant, atrial fibrillation before implant, low LVEF, elevated BNP, chronic kidney disease and follow-up duration after implant.