A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of Dynamic Automated CT Annular Measurements Compared to Standard Manual Measurements for Transcatheter Aortic Valve Replacement Sizing. | LitMetric

Purpose: We sought to determine the performance of an automated computed tomography (CT) software that provides dynamic annular measurements of all available cardiac phases for transcatheter aortic valve replacement (TAVR) sizing as compared to the standard single manual measurement.

Materials And Methods: In 60 TAVR patients (84±7 years, 60% male) who underwent pre-procedural CT scans, we measured the aortic annular diameters, perimeter, and area using (1) the dynamic automated CT measurements and (2) standard single manual measurement from the cardiac phase of maximum systolic opening by visual estimate.

Results: The automated software was successful in providing annular measurements in 43/60 (72%) of cases, with the remainder requiring semi-automated contours. The maximum dynamic automated values were predominantly in systole (46/60[77%] for diameter, 44/60[73%] for perimeter, 48/60[80%] for area), and was a different phase from the standard manual phase in 46/60 (77%) cases. The maximum dynamic automated annular values were larger than the standard manual values measured (Δdiameter 0.35 mm, p=0.04; Δperimeter 1.71 mm, p<0.001; Δarea 15.6 mm, p<0.001). When comparing standard manual to the same phase by automated measurements, while there was no difference in annular mean diameter (p=0.80), perimeter and area were larger with the automated measurements (Δperimeter 0.95 mm, p=0.002; Δarea 10.8 mm, p=0.03). However, the maximum automated measurements were consistently larger than the same phase automated measurements (Δdiameter 0.13 mm, p<0.001; Δperimeter 0.42 mm, p<0.001; Δarea 4.4 mm, p<0.001).

Conclusions: Automated maximum dynamic CT annular measurements provide larger values than standard manual and same phase automated measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6727651PMC
http://dx.doi.org/10.1148/ryct.2019180025DOI Listing

Publication Analysis

Top Keywords

dynamic automated
16
annular measurements
12
standard manual
12
automated annular
8
compared standard
8
transcatheter aortic
8
aortic valve
8
valve replacement
8
standard single
8
single manual
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!