Background: A small proportion of patients undergoing primary prophylactic implantation of implantable cardioverter defibrillators (ICDs) experiences malignant arrhythmias. We postulated that periodic repolarisation dynamics, a novel marker of sympathetic-activity-associated repolarisation instability, could be used to identify electrically vulnerable patients who would benefit from prophylactic implantation of ICDs by way of a reduction in mortality.
Methods: We did a prespecified substudy of EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD), a prospective, investigator-initiated, non-randomised, controlled cohort study done at 44 centres in 15 EU countries. Patients aged 18 years or older with ischaemic or non-ischaemic cardiomyopathy and reduced left ventricular ejection fraction (≤35%) were eligible for inclusion if they met guideline-based criteria for primary prophylactic implantation of ICDs. Periodic repolarisation dynamics from 24-h Holter recordings were assessed blindly in patients the day before ICD implantation or on the day of study enrolment in patients who were conservatively managed. The primary endpoint was all-cause mortality. Propensity scoring and multivariable models were used to assess the interaction between periodic repolarisation dynamics and the treatment effect of ICDs on mortality.
Findings: Between May 12, 2014, and Sept 7, 2018, 1371 patients were enrolled in our study. 968 of these patients underwent ICD implantation, and 403 were treated conservatively. During follow-up (median 2·7 years [IQR 2·0-3·3] in the ICD group and 1·2 years [0·8-2·7] in the control group), 138 (14%) patients died in the ICD group and 64 (16%) patients died in the control group. We noted a 43% reduction in mortality in the ICD group compared with the control group (adjusted hazard ratio [HR] 0·57 [95% CI 0·41-0·79]; p=0·0008). Periodic repolarisation dynamics significantly predicted the treatment effect of ICDs on mortality (adjusted p=0·0307). The mortality benefits associated with ICD implantation were greater in patients with periodic repolarisation dynamics of 7·5 deg or higher (n=199; adjusted HR 0·25 [95% CI 0·13-0·47] for the ICD group vs the control group; p<0·0001) than in those with periodic repolarisation dynamics less than 7·5 deg (n=1166; adjusted HR 0·69 [95% CI 0·47-1·00]; p=0·0492; p=0·0056). The number needed to treat was 18·3 (95% CI 10·6-4895·3) in patients with periodic repolarisation dynamics less than 7·5 deg and 3·1 (2·6-4·8) in those with periodic repolarisation dynamics of 7·5 deg or higher.
Interpretation: Periodic repolarisation dynamics predict mortality reductions associated with prophylactic implantation of ICDs in contemporarily treated patients with ischaemic or non-ischaemic cardiomyopathy. Periodic repolarisation dynamics could help to guide treatment decisions about prophylactic ICD implantation.
Funding: The European Community's 7th Framework Programme.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0140-6736(19)31996-8 | DOI Listing |
Toxics
September 2024
Instituto de Biofísica Carlos Chagas Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-902, RJ, Brazil.
Front Pharmacol
April 2024
Department of Computer Science, University of Oxford, Oxford, United Kingdom.
Hypertrophic cardiomyopathy (HCM) is a leading cause of lethal arrhythmias in the young. Although the arrhythmic substrate has been hypothesised to be amenable to late Na block with ranolazine, the specific mechanisms are not fully understood. Therefore, this study aimed to investigate the substrate mechanisms of safety and antiarrhythmic efficacy of ranolazine in HCM.
View Article and Find Full Text PDFIntroduction: During an acute migraine attack, changes in ventricular repolarisation parameters may occur due to an imbalance in the autonomic nervous system. Tpeak-tend (Tp-e) interval, Tp-e/QT ratio, and Tp-e/corrected QT (QTc) ratio are novel parameters of arrhythmogenesis and can be easily calculated in electrocardiography (ECG). The objective of this study is to demonstrate that novel ventricular repolarisation parameters can anticipate the risk of ventricular dysrhythmia in the migraine attack period.
View Article and Find Full Text PDFSci Rep
July 2023
Department of Molecular Medicine, Aarhus University Hospital, Aarhus, Denmark.
The genetic architecture of the QT interval, defined as the period from onset of depolarisation to completion of repolarisation of the ventricular myocardium, is incompletely understood. Only a minor part of the QT interval variation in the general population has been linked to autosomal variant loci. Altered X chromosome dosage in humans, as seen in sex chromosome aneuploidies such as Turner syndrome (TS) and Klinefelter syndrome (KS), is associated with altered QTc interval (heart rate corrected QT), indicating that genes, located in the pseudoautosomal region 1 of the X and Y chromosomes may contribute to QT interval variation.
View Article and Find Full Text PDFLife Sci
February 2023
School of Health, Medical and Applied Sciences, Central Queensland University, Bruce Highway, Rockhampton, QLD 4701, Australia.
Aims: The therapeutic properties of anti-hypertensive medications that extend beyond blood pressure lowering have started to become important clinical targets in recent years. This study aimed to assess the cardioprotective effects of perindopril in attenuating complications associated with metabolic syndrome in diet induced obese rats.
Main Methods: Male Wistar-Kyoto (WKY) rats aged 16 weeks were fed either standard rat chow (SC) or given a high-fat-high-carbohydrate (HFHC) diet for 20 weeks.