Background: Millions of people carry water home from off-plot sources each day and lack improved sanitation. Research on the health outcomes associated with water fetching is limited, and with usage of improved sanitation is inconclusive.
Objectives: To analyse the association of water fetching, unimproved water supplies, and usage of improved sanitation facilities with indicators of women's and children's health.
Methods: 49 Multiple Indicator Cluster Surveys from 41 countries were merged, creating a data set of 2,740,855 people from 539,915 households. Multilevel, multivariable analyses were conducted, using logistic regression for binary outcomes, negative binomial regression for count data and ordinary linear regression for linear data. We adjusted for confounding factors and accounted for clustering at survey, cluster and household level.
Results: Compared to households in which no-one collects water, water fetching by any household member is associated with reduced odds of a woman giving birth in a health care facility (OR 0.88 to 0.90). Adults collecting water is associated with increased relative risk of childhood death (RR 1.04 to 1.05), children collecting water is associated with increased odds of diarrheal disease (OR 1.10 to 1.13) and women or girls collecting water is associated with reduced uptake of antenatal care (β-0.04 to -0.06) and increased odds of leaving a child under five alone for one or more hours, one or more days per week (OR 1.07 to 1.16). Unimproved water supply is associated with childhood diarhhoea (OR 1.05), but not child deaths, or growth scores. When the percentage of people using improved sanitation is more than 80% an association with reduced childhood death and stunting was observed, and when more than 60%, usage of improved sanitation was associated with reduction of diarhhoea and acute undernutrition.
Conclusion: Fetching water is associated with poorer maternal and child health outcomes, depending on who collects water. The percentage of people using improved sanitation seems to be more important than type of toilet facility, and must be high to observe an association with reduced child deaths and diarhhoea. Water access on premises, and near universal usage of improved sanitation, is associated with improvements to maternal and child health.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijheh.2019.08.007 | DOI Listing |
PLoS One
January 2025
School of Medicine, Institute of Health Science, Jigjiga University, Jigjiga, Ethiopia.
Background: One of the tropical illnesses that is often overlooked is soil-transmitted helminths, or STHs. In tropical and subtropical nations, where poor sanitation and contaminated water sources are common, they mostly impact the most vulnerable populations.
Objective: The aim of this study was to ascertain the prevalence of STHs and related risk factors among the people living in Jigjiga town, Somali region, Eastern Ethiopia.
Water Sci Technol
January 2025
Norwegian University of Life Sciences, Department of Building and Environmental Technology, P.O. Box 5003, 1430 Ås, Norway.
The need for stringent phosphorus removal from domestic wastewater is increasing to mitigate eutrophication, while efficient phosphate reuse is critical due to the global phosphate crisis. Combining aluminum sulfate (ALS) with high molecular weight organic polymers achieved 95-99% removal of particles, turbidity, and phosphates, reducing ALS usage by 40%. We propose mechanisms to explain the enhanced treatment efficiency.
View Article and Find Full Text PDFWater Sci Technol
January 2025
Qingdao Branch of Luoyang Ship Material Research Institute, 149-1, Zhuzhou Road, Laoshan District, Qingdao, Shandong, China; Sunrui Marine Environment Engineering Co., Ltd, Qingdao, Shandong, China.
Nowadays, performance studies on the amperometric total residual oxidant (TRO) sensor are only in the bench test stage and have not been conducted under specific maritime conditions with Ballast Water Management System (BWMS). In this study, the application of the amperometric TRO sensor in land-based biological efficacy (BE) testing, operation and maintenance (O&M) testing, as well as shipboard (SB) testing, was explored by comparing with the existing di-phenylene-diamine (DPD) TRO sensor. The results showed that the average TRO measurement deviation between the amperometric sensor and the DPD sensor was within ±10% in valid BE test cycles and the O&M testing exceeding 47 operating hours.
View Article and Find Full Text PDFWater Sci Technol
January 2025
Center for Sustainable Development, College of Arts and Sciences, Qatar University, Doha 2713, Qatar.
This work focused on the biotreatment of wastewater and contaminated soil in a used oil recycling plant located in Bizerte. A continuous stirred tank reactor (CSTR) and a trickling filter (TF) were used to treat stripped and collected wastewater, respectively. The CSTR was started up and stabilized for 90 days.
View Article and Find Full Text PDFWater Sci Technol
January 2025
Departamento de Biotecnología y Ciencias Alimentarias, Instituto Tecnológico de Sonora (ITSON), 5 de Febrero 818 sur, Ciudad Obregón, Sonora 85000, México E-mail:
Granular activated carbon (GAC) and GAC modified with anthraquinone-2-sulfonate (AQS) were used as conductive materials during the anaerobic digestion of swine wastewater (SW). The electron transfer capacity (ETC) in the GAC-AQS was 2.1-fold higher than the unmodified GAC.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!