Purpose: Upper airway stimulation (UAS) is an effective treatment for obstructive sleep apnea (OSA) in positive airway pressure (PAP) failure. Most reports have presented short-term data, so long-term safety and efficacy reports are rare. The German post-market study (G-PMS) has followed approximately 60 patients from three implanting centers for several years.
Methods: Patients with OSA and PAP failure qualified for the G-PMS by the absence of obesity class 2 an AHI between 15 and 65 events/h and absence of complete concentric collapse at the velum during drug-induced sleep endoscopy. Optional 2- and 3-year follow-ups after implantation were collected during routine clinical practice. We measured respiratory parameters such as apnea-hypopnea index (AHI) and oxygen desaturation index (ODI) and daytime sleepiness using the Epworth sleepiness scale (ESS) in a per protocol analysis. Usage was calculated from device-downloaded reports. Device-related complications were documented.
Results: Of the 60 original patients, 41 returned for 2-year follow-up, and 38 for 3 years. About 76% at 2 years and 68% at 3 years met the criterion of therapy success defined as an AHI below 15/h. The median AHI was reduced from 28.6/h (baseline) to 9.0/h (2 years) and 10.0/h (3 years); whereas median ODI decreased from 27.0 to 6.3/h (2 years), and 8.3/h (3 years). Median ESS improved from baseline 13 points to 4 (2 years) and 6 (3 years). Usage was stable at approximately 45 h per week at 2 and 3 years. Serious device-related adverse events were rare, with two-device explantation between 12 to 36 months postoperatively.
Conclusions: The German multi-center long-term outcomes compare favorably with previously published studies. Respiratory and sleepiness efficacy outcomes were sustained over 2 and 3 years, with a favorable safety profile, supporting the safety and efficacy of a chronic implantable therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11325-019-01933-0 | DOI Listing |
Catheter Cardiovasc Interv
December 2024
Center of Innovative Interventions in Cardiology, University Hospital Bonn, Bonn, Germany.
Background: The self-expanding, supra-annular Evolut valve is an established platform for Transcatheter Aortic Valve Implantation (TAVI). Evolut PRO introduced an outer sealing wrap to mitigate paravalvular leakage. We evaluated the 3-year clinical outcomes and valve performance of the Evolut PRO in standard clinical practice for severe aortic stenosis (AS) patients at intermediate or higher risk for surgery.
View Article and Find Full Text PDFEuropace
July 2024
Department of Electrophysiology, Heart Center at the University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany.
Aims: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients.
View Article and Find Full Text PDFJ Clin Oncol
August 2024
Division of Hematology-Oncology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Background: Detailed, comprehensive, and timely reporting on population health by underlying causes of disability and premature death is crucial to understanding and responding to complex patterns of disease and injury burden over time and across age groups, sexes, and locations. The availability of disease burden estimates can promote evidence-based interventions that enable public health researchers, policy makers, and other professionals to implement strategies that can mitigate diseases. It can also facilitate more rigorous monitoring of progress towards national and international health targets, such as the Sustainable Development Goals.
View Article and Find Full Text PDFJ Neurointerv Surg
April 2024
Imaging Department, Imperial College Healthcare NHS Trust, London, UK
Background: A direct aspiration first pass technique (ADAPT) is an effective alternative to stent retriever thrombectomy for patients with large vessel occlusion (LVO). The PERFECT study evaluated direct aspiration with the EMBOVAC large bore aspiration catheter in patients with LVO strokes.
Methods: PERFECT was a prospective, post-market, single-arm, multicenter, observational study of patients enrolled across 11 European centers between October 2020 and July 2022.