A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Identification and Differentiation of Radix and Radix Preaparata through the Quantitative Analysis of Multicomponents by the Single-Marker Method. | LitMetric

The quantitative analysis of multicomponents by the single-marker (QAMS) method was established and the relationship between value (the ratio of the sum of the contents of emodin-8-O--D-glucopyranoside and physcion-8-O--D-glucopyranoside to the sum of the contents of emodin and physcion) and the steaming time was found to identify and differentiate Radix and its processed product. Emodin was considered as the control substance, and the correction factors of physcion, emodin-8-O--D-glucopyranoside, and physcion-8-O--D-glucopyranoside were computed. In addition, the contents of the four components were determined. When the value is greater than or equal to 1.0, the sample was identified as Radix, and if the value was between 0.6 and 1.0, the sample of Radix Preaparata was processed incompletely. The value of the qualified Radix should be no more than 0.6. However, the influence of different sample injection volumes and the chromatographic columns and instruments used on the durability of the correction factors and RSD ≤3% hindered accurate identification; therefore, a QAMS method using an external standard value with methodological verification was developed. We redefined the " rules." The method using " rules" revised after optimization of the determination results was used, as it was accurate and led to convenient operation and low inspection costs, and moreover, the method could differentiate Radix Preaparata and Radix medicinal samples and precisely identify samples that were different from the completely processed product Radix Preaparata.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702820PMC
http://dx.doi.org/10.1155/2019/7430717DOI Listing

Publication Analysis

Top Keywords

radix preaparata
16
radix
9
quantitative analysis
8
analysis multicomponents
8
multicomponents single-marker
8
qams method
8
sum contents
8
emodin-8-o--d-glucopyranoside physcion-8-o--d-glucopyranoside
8
differentiate radix
8
processed product
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!