Broadband and multi-resonant sensors for NMR.

Prog Nucl Magn Reson Spectrosc

Institute of Microstructure Technology (IMT), Karlsruhe Institute of Technology (KIT), Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Baden-Württemberg, Germany. Electronic address:

Published: March 2020

It has always been of considerable interest to study the nuclear magnetic resonance response of multiple nuclei simultaneously, whether these signals arise from internuclear couplings within the same molecule, or from uncoupled nuclei within sample mixtures. The literature contains numerous uncorrelated reports on techniques employed to achieve multi-nuclear NMR detection. This paper consolidates the subset of techniques in which single coil detectors are utilized, and highlights the strengths and weaknesses of each approach, at the same time pointing the way towards future developments in the field of multi-nuclear NMR. We compare the different multi-nuclear NMR techniques in terms of performance, and present a guide to NMR probe designers towards application-based optimum design. We also review the applicability of micro-coils in the context of multi-nuclear methods. Micro-coils benefit from compact geometries and exhibit lower impedance, which provide new opportunities and challenges for the NMR probe designer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.pnmrs.2019.05.001DOI Listing

Publication Analysis

Top Keywords

multi-nuclear nmr
12
nmr probe
8
nmr
6
broadband multi-resonant
4
multi-resonant sensors
4
sensors nmr
4
nmr considerable
4
considerable interest
4
interest study
4
study nuclear
4

Similar Publications

Article Synopsis
  • Conventional kidney function tests like glomerular filtration rate offer limited insight, while advanced multi-parametric and multi-nuclear MRI techniques provide a more comprehensive understanding of kidney physiology, including assessing perfusion and tissue characteristics without invasive methods.
  • Multi-parametric MRI can evaluate critical aspects of kidney health, such as fibrosis and oxygenation, while multi-nuclear MRI techniques like sodium and phosphorus MRI enable insights into sodium storage and oxidative metabolism, relevant for conditions like chronic kidney disease.
  • These non-invasive MRI techniques are particularly advantageous for pediatric patients, allowing for longitudinal assessments and improved understanding of kidney function with minimal risk and short acquisition times.
View Article and Find Full Text PDF

Dual-tuned floating solenoid balun for multi-nuclear MRI and MRS.

Magn Reson Imaging

January 2025

Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA. Electronic address:

Common-mode currents can degrade the RF coil performance and introduce potential safety hazards in MRI. Baluns are the standard method to suppress these undesired common-mode currents. Specifically, floating baluns are preferred in many applications because they are removable, allow post-installation adjustment and avoid direct soldering on the cable.

View Article and Find Full Text PDF

Simultaneous multinuclear MRI via a single RF channel.

J Magn Reson

November 2024

Karlsruhe Institute of Technology (KIT), Institute of Microstructure Technology, Karlsruhe 76131, Germany. Electronic address:

Magnetic resonance imaging (MRI) stands as one of the most powerful noninvasive and non-destructive imaging techniques, finding extensive utility in medical and industrial applications. Its ability to acquire signals from multiple nuclei grants it additional levels of strength by providing multi-dimensional datasets of the object under test. However, this typically requires dedicated hardware to detect each nucleus.

View Article and Find Full Text PDF

Frequency-independent dual-tuned cable traps for multi-nuclear MRI and MRS.

J Magn Reson

November 2024

Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA; Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA. Electronic address:

Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) of non-proton nuclei (X-nuclei) typically require additional proton imaging for anatomical reference and B shimming. Therefore, two RF systems exist, necessitating cable traps to block the unwanted common-mode current at both Larmor frequencies of H and X-nuclei. This study introduces a frequency-independent dual-tuned cable trap that combines a standard solenoid cable trap with a float solenoid trap to independently tune high and low frequencies without compromising performance.

View Article and Find Full Text PDF

Non-invasive brain imaging has played a critical role in establishing our understanding of the neural properties that contribute to the emergence of psychiatric disorders. However, characterizing core neurobiological mechanisms of psychiatric symptomatology requires greater structural, functional, and neurochemical specificity than is typically obtainable with standard field strength MRI acquisitions (e.g.

View Article and Find Full Text PDF