A simple sleep monitoring measurement method is presented in this paper, based on a simple, non-invasive motion sensor, the Passive InfraRed (PIR) motion sensor. The easy measurement set-up proposed is presented and its performances are compared with the ones provided by a commercial, ballistocardiographic bed sensor, used as reference tool. Testing was conducted on 25 nocturnal acquisitions with a voluntary, healthy subject, using the PIR-based proposed method and the reference sensor, simultaneously. A dedicated algorithm was developed to correlate the bed sensor outputs with the PIR signal to extract sleep-related features: sleep latency (SL), sleep interruptions (INT), and time to wake (TTW). Such sleep parameters were automatically identified by the algorithm, and then correlated to the ones computed by the reference bed sensor. The identification of these sleep parameters allowed the computation of an important, global sleep quality parameter: the sleep efficiency (SE). It was calculated for each nocturnal acquisition and then correlated to the SE values provided by the reference sensor. Results show the correlation between the SE values monitored with the PIR and the bed sensor with a robust statistic confidence of 4.7% for the measurement of SE (coverage parameter k = 2), indicating the validity of the proposed, unobstructive approach, based on a simple, small, and low-cost sensor, for the assessment of important sleep-related parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6749559PMC
http://dx.doi.org/10.3390/s19173773DOI Listing

Publication Analysis

Top Keywords

bed sensor
16
sensor
9
assessment sleep-related
8
sleep-related parameters
8
passive infrared
8
based simple
8
motion sensor
8
reference sensor
8
sleep parameters
8
sleep
7

Similar Publications

Novel Design on Knee Exoskeleton with Compliant Actuator for Post-Stroke Rehabilitation.

Sensors (Basel)

December 2024

Institute of Robotics, Autonomous System and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK.

Knee joint disorders pose a significant and growing challenge to global healthcare systems. Recent advancements in robotics, sensing technologies, and artificial intelligence have driven the development of robot-assisted therapies, reducing the physical burden on therapists and improving rehabilitation outcomes. This study presents a novel knee exoskeleton designed for safe and adaptive rehabilitation, specifically targeting bed-bound stroke patients to enable early intervention.

View Article and Find Full Text PDF

Mattress firmness is a critical factor influencing sleep quality. This study investigates the effects of time, mattress firmness, and anthropometric parameters on surface electromyographic (sEMG) activity during supine rest. Eleven participants were analyzed, and the values for lower back sEMG on three mattresses were measured as 8.

View Article and Find Full Text PDF

Fatigue and recovery-related changes in postural and core stability in sedentary employees: a study protocol.

Front Physiol

December 2024

Department of Biological and Medical Sciences, Faculty of Physical Education and Sport, Comenius University in Bratislava, Bratislava, Slovakia.

Prolonged sitting leads to a slumped posture, which indirectly influences spinal curvature and increases low back and hamstring stiffness. Active rather than passive recovery is an effective way to reduce the risks associated with such prolonged inactivity. However, it remains to be investigated which of the exercises frequently used for this purpose, the trunk stability and foam rolling exercise, is more beneficial.

View Article and Find Full Text PDF

Background: The dosage and intensity of physical therapy are crucial factors influencing the motor recovery of the hemiplegic lower limb in patients with subacute stroke. Biofeedback using wearable sensors may provide opportunities for patients with stroke to effectively guide self-exercises with monitoring of muscular activities in hemiplegic lower limbs. This study aims to explore the feasibility and safety of in-bed self-exercises based on electromyography sensor feedback in patients with subacute stroke.

View Article and Find Full Text PDF

Background/objectives: Measuring the physical functioning of older hip fracture patients using wearables is desirable, with physical activity monitoring offering a promising approach. However, it is first important to assess physical activity in healthy older adults. This study quantifies physical functioning with physical activity parameters and assesses those parameters in community-dwelling older adults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!