Background: Therapeutic drug monitoring (TDM) of tacrolimus (Tac) is mandatory in renal transplant recipients (RTxR). Area under the concentration versus time curve (AUC) is the preferred measure for Tac exposure; however, for practical purposes, most centers use trough concentrations as a clinical surrogate. Limited sampling strategies in combination with population pharmacokinetic model-derived Bayesian estimators (popPK-BE) may accurately predict individual AUC. The use of self-collected capillary microsamples could simplify this strategy. This study aimed to investigate the potential of AUC-targeted Tac TDM using capillary microsamples in combination with popPK-BE.

Methods: A single-center prospective pharmacokinetic study was conducted in standard-risk RTxR (n = 27) receiving Tac twice daily. Both venous and capillary microsamples (Mitra; Neoteryx, Torrance, CA) were obtained across 2 separate 12-hour Tac dosing intervals (n = 13 samples/AUC). Using popPK-BE, reference AUC (AUCref) was determined for each patient using all venous samples. Different limited sampling strategies were tested for AUC predictions: (1) the empiric sampling scheme; 0, 1, and 3 hours after dose and (2) 3 sampling times determined by the multiple model optimal sampling time function in Pmetrics. Agreement between the predicted AUCs and AUCref were evaluated using C-statistics. Accepted agreement was defined as a total deviation index ≤±15%.

Results: The AUC from capillary microsamples revealed high accuracy and precision compared with venous AUCref, and 85% of the AUCs had an error within ±11.9%. Applying microsamples at 0, 1, and 3 hours after dose predicted venous AUCref with acceptable agreement. Patients performed self-sampling with acceptable accuracy.

Conclusions: Capillary microsampling is patient-centered, making AUC-targeted TDM of Tac feasible without extended hospital stays. Samples obtained 0, 1, and 3 hours after dose, combined with popPK-BE, accurately predict venous Tac AUC.

Download full-text PDF

Source
http://dx.doi.org/10.1097/FTD.0000000000000697DOI Listing

Publication Analysis

Top Keywords

capillary microsamples
16
hours dose
12
area concentration
8
concentration versus
8
versus time
8
time curve
8
capillary microsampling
8
limited sampling
8
sampling strategies
8
poppk-be accurately
8

Similar Publications

Background: Virus neutralising antibodies in serum are considered key correlates of protection for vaccines and monoclonal antibodies against respiratory syncytial virus (RSV). RSM01 is a novel, highly-potent, half-life-extended and fully-human monoclonal antibody candidate targeting the RSV prefusion F protein. Currently in Phase 1 development, RSM01 is primarily being developed to potentially provide an effective and affordable RSV prevention strategy in low- and middle-income countries.

View Article and Find Full Text PDF

Development and validation of a quantification method for direct oral anticoagulants from capillary blood using volumetric absorptive microsampling and online SPE-LC-MS.

J Chromatogr B Analyt Technol Biomed Life Sci

January 2025

Department of Pharmaceutical and Medical Chemistry, Clinical Pharmacy, University of Muenster, Muenster, Germany. Electronic address:

The number of prescriptions for new direct oral anticoagulants (DOACs) apixaban, edoxaban, rivaroxaban and dabigatran has increased exponentially in recent years, increasingly replacing the old gold standard, vitamin-K-antagonists. Due to their wide therapeutic range, therapeutic drug monitoring (TDM) is not required, although it has been proven that this could significantly reduce side effects. In order to develop a cost-efficient and simple method for the simultaneous detection of the DOACs and phenprocoumon, a new technology for sample preparation from capillary blood in the ambulant sector named VAMS® was integrated and an LC-MS detector with on-line solid phase extraction (SPE) applying a Turboflow HTLC Cyclone 1.

View Article and Find Full Text PDF

An off-the-shelf Agilent 7100 capillary electrophoresis (CE) instrument was employed for the automated processing and analysis of dried blood spots (DBSs) collected by Capitainer®B volumetric devices. Solutions for DBS elutions were transferred directly into CE vials through a separation capillary by the application of an auxiliary nitrogen gas connected to the external pressure line of the CE instrument. This allowed for liquid handling at pressures up to 15 bar and enabled the use of a single capillary for rapid DBS processing and efficient CE separations.

View Article and Find Full Text PDF

Background: Hyperkalemia is common in kidney transplant (KTx) recipients. Patiromer, a potassium-binding polymer used to treat acute and chronic hyperkalemia, has the potential to bind charged particles in the gastrointestinal tract and thereby potentially affect the absorption of coadministered drugs. The immunosuppressive drug tacrolimus (Tac) has a narrow therapeutic window, is susceptible to drug-drug interactions (DDIs), and a potential gastrointestinal interaction with patiromer could elevate the risk of allograft rejection.

View Article and Find Full Text PDF
Article Synopsis
  • The study develops a high-throughput assay to measure peptides from type III procollagen in human serum, addressing limitations of existing immunoassays used for growth hormone detection.
  • The new method utilizes a combination of immunoaffinity enrichment and ultra-high-performance liquid chromatography-tandem mass spectrometry, resulting in good accuracy and precision for quantifying the peptides.
  • While this method shows a decent correlation to a standard immunoassay, significant bias indicates a need for standardized calibrators to improve result consistency across different laboratories.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!