A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of real-time PCR assay allowed describing the first clinical Klebsiella pneumoniae isolate harboring plasmid-mediated colistin resistance mcr-8 gene in Algeria. | LitMetric

Objectives: We aimed to develop here a specific real-time PCR assay with TaqMan® probe to detect efficiently bacterial strains harboring the new plasmid mediated-colistin resistance mcr-8 gene.

Methods: Specific primers and probe for mcr-8 gene were designed from sequences alignment of all mcr genes variants. Specificity of the designed primers and probe were first checked par BlastN analysis and by in silico PCR. The analytical sensitivity and specificity tests were performed in vitro on a panel of 290 genomic DNA of Gram-negative bacteria and 250 metagenomic DNA from human stool samples. Whole genome sequencing (WGS) was performed here using MiSeq technology.

Results: Designed primers and probe were 100% specific tomcr-8 gene by BlastN and in silico PCR analysis. Real-time PCR screening of a collection of clinical isolates resulted to one positive Klebsiella pneumoniae isolate (KP95). WGS confirmed that this isolate harbored the mcr-8 gene and other resistance genes such as bla, bla β-lactamases. Our real-time PCR was highly sensitive on a 10-fold dilution serie from a calibrated inoculum at 10 CFU/mL with a limit of detection at 55 CFU/mL.

Conclusion: To the best of our knowledge, we propose here, the first real-time PCR assay targeting mcr-8 gene with high specificity and sensitivity, able to detect mcr-8 gene in less than 2 h from any DNA sample. This real-time PCR assay allowed the first description of a clinical K. pneumoniae strain harboring the mcr-8 gene in Algeria.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jgar.2019.08.018DOI Listing

Publication Analysis

Top Keywords

real-time pcr
24
mcr-8 gene
24
pcr assay
16
primers probe
12
pcr
8
assay allowed
8
klebsiella pneumoniae
8
pneumoniae isolate
8
resistance mcr-8
8
gene algeria
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!