Aim: To present a new protocol to optimise ultrasound (US) assessment of haemophilic arthropathy.
Materials And Methods: Ultrasound of haemophilic arthropathy joints was performed using three different ultrasound protocols, namely, the Toronto-Vellore Comprehensive Ultrasound (TVC-US) protocol, the Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US), and the newly developed Universal Simplified Ultrasound (US-US) protocol. Synovial hypertrophy, haemosiderin deposition, effusion, erosion, and cartilage loss were evaluated in 20 joints. The reliability and diagnostic efficiency of these protocols was compared using magnetic resonance imaging (MRI).
Results: The correlation between the TVC-US and US-US protocols for synovial hypertrophy was excellent: kappa significance (KS) was 1, but was substantial (KS=0.65) with the HEAD-US protocol. For effusion, both the TVC-US and the HEAD-US protocols had substantial correlation with the US-US protocol (KS=0.7 and 0.6 respectively). The correlation for erosion and cartilage loss was excellent between the TVC-US and the US-US with MRI (KS=1), but poor (KS=0) with the HEAD-US protocol. The US-US protocol also had good interobserver agreement (KS=1).
Conclusion: The accuracy of the US-US protocol is comparable to the TVC-US protocol and MRI and is superior to the HEAD-US protocol in the assessment of haemophilic arthropathy.