A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Gravity and rheotaxis based sperm sorting device employing a cam-actuated pipette mechanism. | LitMetric

Gravity and rheotaxis based sperm sorting device employing a cam-actuated pipette mechanism.

Rev Sci Instrum

School of Aerospace and Mechanical Engineering, Korea Aerospace University, Goyang-si, Gyeonggi-do, 10540, South Korea.

Published: August 2019

Until now, a swim-up or microchip-based method has been mainly utilized for separating normal sperm for use in assisted reproductive technology. However, it requires excessive sorting time due to preprocessing and collects a limited number of motile sperms. To improve this process, we propose a gravity-fed high motility sperm sorting device that utilizes the rheotaxis of sperm, which minimizes separation time and improves throughput. The device features a mesoscale microfluidic channel to maximize the throughput, and an outlet at the bottom is configured to control the fluid velocity in the channel by using gravity. To control and automate semen injection and suction of the sorted sperm, a pipette controller using a cam was fabricated. After constructing the system, a sorting experiment was performed using canine semen to confirm the separation efficiency. After injecting the semen in the channel, the delay time between injection and suction was measured and the relative improvement of the index of motility was investigated according to measured delay time. As a result of repeated experiments, it was confirmed that the highest improvement was obtained at a delay time of 80 s, and the mean velocity, %motility, MI, and motile sperm rates were improved by 8.94%, 32.58%, 35.48%, and 21.99%, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.5096793DOI Listing

Publication Analysis

Top Keywords

delay time
12
sperm sorting
8
sorting device
8
injection suction
8
sperm
6
time
5
gravity rheotaxis
4
rheotaxis based
4
based sperm
4
sorting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!