This paper describes the design, simulation, development, and analysis of a Cross Floating Valve (CFV), an important instrument used in a cross float or pressure calibration system of pressure balances (PBs) to make the calibration process easy and time efficient. The design aspects of the CFV include the selection of proper materials and modeling of various necessary components of the CFV. For the piston design, 5 different materials, SS304, SS316, Aermet 340, SS440C, and AISI17-4PH were used. After the design, simulation studies were carried out using the ANSYS (Workbench R15.0) software to understand the behavior of stress, strain, and deformation. Out of the 5 materials thus used, the values of the factor of safety of 2 materials (SS304 and SS316) were found to be below expectations and hence were not used in the fabrication process. Among the rest of the 3 other materials (AISI17-4PH, SS440C, and Aermet 340) having a factor of safety within the expected limits, Aermet 340 was also ignored because of its high cost. Finally, AISI17-4PH and SS440C were used to fabricate the piston, the most important and critical component of the CFV. The final CFV thus developed was tested for its performance in the cross floating experiments with 2 different sets of PBs. The results thus obtained show that the use of CFV reduces the calibration time considerably which is approximately 30% (average time of increasing and decreasing orders of pressure) from the time taken in performing calibration without using CFV, which is a significant achievement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.5089953 | DOI Listing |
Front Public Health
January 2025
Division of Medical Statistics and Bioinformatics, Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan.
Background: Taiwan implemented global hospital budgeting with a floating-point value, which created a prisoner's dilemma. As a result, hospitals increased service volume, which caused the floating-point value to drop to less than one New Taiwan Dollar (NTD). The recent increase in the number of hospital beds and the call to enhance the floating-point value to one NTD raise concerns about the potential for increased financial burden without adding value to patient care if hospitals expand their bed capacity for volume-based competition.
View Article and Find Full Text PDFA 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
School of Mechanical Engineering, Southwest Petroleum University, Chengdu, Sichuan 610500, China.
Efficient identification of the flocculation state of waste drilling fluid remains a significant challenge. This study proposes an improved You Only Look Once version 8 nano-algorithm (YOLOv8n), specifically optimized for real-time monitoring of drilling fluid flocculation under field conditions. The algorithm employs MobileNetV3 as the backbone network to minimize memory usage, improve detection speed, and reduce computational requirements.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Chemistry, University of Wisconsin─Madison, Madison, Wisconsin 53706, United States.
Scaffolding catalytic reactions within porous materials is a powerful strategy to enhance the reaction rates of multicatalytic systems. However, it remains challenging to develop materials with high porosity, high diversity of functional groups within the pores, and guest-adaptive tunability. Furthermore, it is challenging to capture large catalysts such as enzymes within porous materials.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!