We report a new 7-nitrobenzo-2-oxa-1, 3-diazolyl (NBD)-based chemosensor containing a piperazine derivative, NBDP, for detection of mercury ions in almost 100% aqueous medium. The chemosensor shows sensing exclusively toward Hg with a switch-on fluorescence response at 543 nm, which could be attributed to the blocking of PET (photo-induced electron transfer) process upon complexation with mercury ions. The molar ratio of Hg(Ⅱ) to NBDP in the complex is 1:1 based on the Job's plot and HRMS studies. Optimized configurations of NBDP and NBDP-Hg complexes were simulated by means of DFT calculations. The reversible fluorescence response with low detection limit (19.2 nM) in the pH range of 6.0-7.5 renders NBDP a promising candidate for Hg detection in neutral aqueous environments. For the practical application of the chemosensor, test strips were successfully fabricated for rapid detection of Hg ions. Moreover, the utility of NBDP showing the mercury recognition in Human liver cancer cells (SMMC-7721) and zebrafish as well as in live tissues of Arabidopsis thaliana has been demonstrated as monitored by fluorescence imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2019.121056DOI Listing

Publication Analysis

Top Keywords

mercury ions
8
fluorescence response
8
nbdp
5
colorimetric fluorometric
4
chemosensor
4
fluorometric chemosensor
4
chemosensor selective
4
selective sensing
4
sensing near-perfect
4
near-perfect aqueous
4

Similar Publications

Heavy metal contamination of drinking water, primarily driven by industrial activities, represents a critical challenge, with implications for human health and environmental safety. Gujranwala is an industrial and thickly populated city. The current study aimed to assess and compare heavy metal contamination levels in drinking water from five industrial areas and evaluate their potential impacts on human health.

View Article and Find Full Text PDF

Research on perovskite light-emitting diodes (PeLEDs) has primarily focused on modulating crystal growth to achieve smaller grain sizes and defect passivation using organic additives. However, challenges remain in controlling the intermolecular interactions between these organic additives and perovskite precursor ions for precise modulation of crystal growth. In this study, we synthesize two triphenylphosphine oxide (TPPO)-based multidentate additives: bidentate hexane-1,6-diyl-bis(oxy-4-triphenylphosphine oxide) (2-TPPO) and tetradentate pentaerythrityl-tetrakis(oxy-4-triphenylphosphine oxide) (4-TPPO).

View Article and Find Full Text PDF

Biogenic Synthesis of Silver Nanoparticles for Nanosensor-Based Mercury Detection.

Luminescence

December 2024

Department of Chemistry, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, Tamil Nadu, India.

The production of nanoparticles via green methods is a developing study domain due to potential environmental applications. The green synthesis method is very easy, less toxic and eco-friendly when compared to the chemical synthesis method. This study addresses the silver nanoparticle synthesis utilizing the Acorus calamus leaf extract, which was then employed for environmental applications.

View Article and Find Full Text PDF

A method for the rapid detection of heavy metal mercury ions based on a novel mercury chelator N,N'-bis (2-mercaptoethyl) isophthalamide.

Food Chem

December 2024

Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai 200234, China. Electronic address:

Mercury has caused severe harm to the environment and human health. A novel biological screen method was developed and identified a Hg chelator BDTH2. Both biological and chemical methods demonstrated BDTH2 displayed a high specificity and strong binding capacity for Hg.

View Article and Find Full Text PDF

Herein, we have used a simple synthetic strategy to access a novel non-sulfur fluorescent molecular probe coumarin and 1,8-napthyridine conjugated probe DNCS. The developed probe has great selectivity and sensitivity for detecting Hg ions. Our photophysical properties evaluation for the synthesized probe with different metal ions (Ba, Al, Ca, Bi, Ce, Cd, Cu, Sr, Co, Fe, Cr, Fe, Mn, Hg, Zn, Pb, Ni, and Sn) unveiled the very selective and sensitive fluorescence sensing behavior with Hg ions in the energy window of near UV and visible light radiation in an organic aqueous solvent mixture (EtOH and water).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!