In order to achieve regulatory compliance and acquire authorisation for sale in Europe, each medical device must be supported by a clinical evaluation report (CER) which documents the clinical evaluation process in its entirety. This is not a new requirement but highly publicised scandals caused by defective medical devices increased scrutiny of notified bodies (the organisations designated by the European Union to evaluate medical device compliance) meaning they are more liable and must strengthen their inspections of medical device manufacturers. Manufacturers are already under increased pressure due to the new EU Medical device regulation published in 2017. The scope of the new regulation requires many manufacturers to evaluate the documentation for their whole product portfolio. CERs are an important part of regulatory compliance and are also one of the biggest challenges for manufacturers who do not have sufficient resources and do not dedicate enough time to this task. This article examines the background of this requirement while offering medical device manufacturers advice for successful clinical evaluation reports.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1684/abc.2019.1473 | DOI Listing |
J Orthop Surg Res
January 2025
Guizhou Medical University, Beijing Jishuitan Hospital Guizhou Hospital, Guiyang, Guizhou, People's Republic of China.
Background: Wound repair methods are commonly used in clinical practice, such as skin graft and flap repair, which can cause secondary injuries, and high costs. Many methods for skin stretching and repair have been reported domestically and internationally. However, their clinical use is limited owing to lack of equipment, complexity, and high costs.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.
Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.
Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.
BMC Public Health
January 2025
School of Economics, Shandong University of Technology, Zibo, 255000, PR China.
In recent years, the government has promoted the increased deployment of automated external defibrillators (AEDs) in public places with dense crowds, which is of great significance for ensuring that residents enjoy equal health rights. However, it is still unclear what factors decision-makers take into account when formulating deployment plans and whether these factors are related to local characteristics such as population distribution and socioeconomic conditions. Taking Shanghai, China as the research area, we adopted the kernel density estimation and spatial autocorrelation analysis to explore the spatial distribution characteristics of AEDs.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Professor of Conservative Dentistry, Faculty of Dentistry, Cairo University, Giza, Egypt.
Background: Minimally invasive dentistry is now becoming the forefront of restorative dentistry, involving less traumatic treatment protocols, conservation of tooth structure and surrounding tissues, enhancing the long-term survivability of treated teeth, and improving the overall quality of life for patients.
Objective: The current case report was conducted to evaluate acquiring deep subgingival interproximal carious lesions by the mean of thermacut bur gingivectomy, in terms of patient satisfaction through pain evaluation, Bleeding on Probing, Pocket Depth, Crestal Bone Level evaluation, and restoration evaluation using modified USPHS criteria.
Material And Methods: A patient with a deep proximal cavity in the posterior tooth was thoroughly examined and underwent Thermacut Bur Gingivectomy (TBG) after caries removal followed by direct resin composite restoration of the prepared cavity.
BMC Nephrol
January 2025
Medical Department III, Division of Nephrology, University Hospital Leipzig, Leipzig, Germany.
Background: Rhabdomyolysis is frequently associated with acute kidney injury (AKI). Due to the nephrotoxic properties of myoglobin, its rapid removal is relevant. If kidney replacement therapy (KRT) is necessary for AKI, a procedure with effective myoglobin elimination should be preferred.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!