Studies of thermal sensitivity in ectotherms require accurate measurements of body temperature using a reliable device, including in field situations. In this study, we tested the accuracy of a compact and inexpensive mini-infrared thermometer (mini-IRT, 22.3 g) at close distance (within 5 mm) for measuring skin surface temperature of small lizards or their models (painted copper bars). First, we used copper bars to assess the effect of model width on the accuracy of the measurement. We placed the heated models on a cool background, and then surface temperatures were measured with a mini-IRT for comparison with a thermogram from an infrared camera (IRC). We also assessed the accuracy of the mini-IRT for measuring skin temperature for two species of small lizards in the laboratory and in the field, in comparison with the skin surface temperature measured with the IRC and with cloacal temperature measured with a thermocouple thermometer. Our results with inanimate models show that the accuracy of the mini-IRT at a distance within 5 mm is biologically acceptable (within ±1.0 °C of the mean value obtained using a more expensive, calibrated device) when the width is ≥ 7 mm. For live lizards, we observed highly significant relationships between skin surface temperature measured with the mini-IRT and temperatures measured with the two other devices. The mean discrepancies between the mini-IRT and other devices were acceptably small for geckos but larger for the smaller and more slender skinks. Taken together, our results suggest that skin temperature measured with the mini-IRT at a close distance is acceptable for field studies on lizards with an abdominal width ≥7 mm, serving as an inexpensive proxy for core body temperature in situations where portability and affordability of equipment and minimal animal handling are paramount. Nonetheless, calibration of mini-IRTs before use is strongly recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtherbio.2019.07.016DOI Listing

Publication Analysis

Top Keywords

skin surface
16
surface temperature
16
temperature measured
16
measuring skin
12
small lizards
12
measured mini-irt
12
temperature
9
temperature small
8
body temperature
8
close distance
8

Similar Publications

The current research emphasis is on the development of wound dressings that can inhibit bacterial infections and facilitate the treatment of complex wound healing processes. In this study, nanofibrous mats of polyvinyl alcohol/chitosan/ZIF-67(PVA/Cs/ZIF-67) were prepared using an electrospinning technique, to investigate their antibacterial and regenerative properties in a rat model of full-thickness skin wounds. ZIF-67 nanoparticles, with an average size of approximately 373.

View Article and Find Full Text PDF

Janus Membrane-Based Wearable Dual-Channel SERS Sensor for Sweat Collection and Monitoring of Lactic Acid and pH Levels.

Anal Chem

March 2025

School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, 44 West Culture Road, Ji'nan 250012, China.

Sweat, as a metabolic byproduct, encompasses a diverse array of molecular information pertinent to our physiological states and overall health. The extraction of minute quantities of sweat, coupled with sensitive monitoring and identification of its internal molecular components, constitutes an effective strategy for assessing bodily conditions. We engineer a Janus membrane utilizing electrospinning techniques for application on human skin to facilitate sweat collection.

View Article and Find Full Text PDF

Basic science research is vital for advancing the emerging field of bone-anchored limb replacement (BALR), or osseointegration (OI). This article discusses clinical challenges for BALR/OI, summarizes current basic science research regarding those challenges, identifies research gaps, and proposes future directions. OI research draws from related fields such as orthopaedic implants and dentistry.

View Article and Find Full Text PDF

Background: Burn wounds are commonly encountered in clinical settings and the management aims at the prevention of mortality and morbidity due to disability. The platelet-rich plasma (PRP) is blood-derived biomaterial that is enriched with growth factors and cytokines that facilitate wound healing. The PRP has proven its efficacy in various other wounds, but its role in post-burn raw areas and graft take has not been validated.

View Article and Find Full Text PDF

Fluids possessing advanced thermal capabilities are a requirement of today's world scientific technology and are an inherent vital part of diversified large-scale processes. As a result, the induction of nanometric-sized particles has been considered an emerging approach to achieve advanced liquids. Various combinations have been used to enhance the efficiency of nanofluids in thermal engineering systems.

View Article and Find Full Text PDF