AI Article Synopsis

  • The study aimed to investigate the impact of intramedullary nail (IMN) diameter, insertion method (antegrade vs. retrograde), and the difference in canal and IMN diameter on healing rates of femoral shaft fractures.
  • A retrospective analysis of 484 femoral shaft fractures treated with IMN showed a high healing rate of 94.2%, with minimal complications and no correlation between healing rates and factors like IMN size or insertion technique.
  • The findings suggest that a 10 mm diameter IMN is a reliable standard for effective treatment, as healing rates remained consistent regardless of the variations in diameter and insertion method.

Article Abstract

Objective: To determine whether intramedullary nail (IMN) diameter, antegrade versus retrograde insertion, or the difference between the canal and IMN diameter affect femoral shaft fracture healing.

Design: Retrospective analysis of a prospective database.

Setting: Level One Regional Trauma Center.

Patients/participants: Seven hundred thirty-three femoral shaft fractures (OTA/AO 32) treated with an IMN between 1999 and 2017. After exclusion criteria, 484 fractures remained in the final analysis.

Intervention: Closed section, cannulated, interlocked, titanium alloy IMN using a reamed insertion technique.

Main Outcome Measurements: Nonunion, IMN size (10, 11.5, and 13 mm), antegrade versus retrograde insertion, Δ canal-nail diameter (ΔD) after reaming (<1, 1-2, or >2 mm).

Results: IMN diameters used were as follows: 314/10 mm (64%), 137/11.5 mm (28%), and 33/13 mm (8%). Forty-five percent were placed in antegrade versus 55% retrograde. Four hundred fifty-six fractures (94.2%) healed uneventfully. There were no IMN failures. 10/484 IMNs (2%) had broken interlocking screws; only 4 were associated with a NU. Average time to union was 23 weeks (12-119). Twenty-eight (5.8%) developed NU. There was no statistical correlation between (1) the NU rate and IMN diameter: 10 mm, 6.3%; 11.5 mm, 5.1%; 13 mm, 3% (P = 0.8, power = 0.85), (2) the NU rate and ΔD: 7.1% <1 mm, 5.6% 1-2 mm, 20% >2 mm (P = 0.36), (3) the NU rate and fracture location: Prox = 11%, Mid = 5%, Dist = 3% (P = 0.13), or (4) the NU rate and antegrade (7.2%) versus retrograde (4.2%) insertion (P = 0.24).

Conclusion: Similar healing rates occurred regardless of IMN diameter, Δ canal-nail diameter after reaming, or insertion site. This indicates that a closed section, cannulated, interlocked, titanium alloy IMN with a diameter of 10 mm can be considered the standard diameter for the treatment of acute femoral shaft fractures, regardless of entry point. This should be associated with less reaming and therefore shorter operative times, and possibly less hospital implant inventories as well. Larger diameter IMN should be reserved for revision surgery.

Level Of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0000000000001585DOI Listing

Publication Analysis

Top Keywords

imn diameter
20
femoral shaft
16
shaft fractures
12
antegrade versus
12
versus retrograde
12
imn
11
diameter
9
insertion canal-nail
8
retrograde insertion
8
closed cannulated
8

Similar Publications

Introduction: Intramedullary femoral nails (IMFNs) need to be removed for subsequent joint replacement, refracture, nonunion, or infection. The tools used to extract newer IMFNs may not be suited for removal of older implants, especially if broken. The purpose of this study was to describe a novel technique in femoral nail extraction when primary measures fail and a report on 6 cases where it was used.

View Article and Find Full Text PDF

FixThePig: a custom 3D-printed femoral intramedullary nailing for preclinical research applications.

Front Bioeng Biotechnol

October 2024

Neuro Musculo Skeletal Lab (NMSK), Institut de Recherche Expérimentale et Clinique (IREC), Université Catholique de Louvain (UCLouvain), Bruxelles, Belgium.

Background: Critical-size bone defects (CSBDs) pose significant challenges in clinical orthopaedics and traumatology. Developing reliable preclinical models that accurately simulate human conditions is crucial for translational research. This study addresses the need for a reliable preclinical model by evaluating the design and efficacy of a custom-made 3D-printed intramedullary nail (IMN) specifically for CSBDs in minipigs.

View Article and Find Full Text PDF

Sub-estrus buffaloes do not exhibit estrus signs despite being cyclic contributing to extended service periods and inter-calving intervals causing significant economic loss. The present study described the effect of synthetic prostaglandin (PGF) on estrus behaviour, follicular and luteal morphometry, and serum estradiol (E) and progesterone (P) profile in sub-estrus buffaloes during the non-breeding season. The incidence of sub-estrus was 38.

View Article and Find Full Text PDF

Sub-estrus is a condition when buffaloes do not display behavioural estrus signs, despite being in estrus and causes a delay in conception and increases the service period. The present study describes the effect of synthetic prostaglandin (PGF) alone and in combination with trace minerals on the follicular and corpus luteum (CL) dynamics, serum estradiol (E) and progesterone (P) concentration correlating estrus response and pregnancy outcome in sub-estrus buffaloes during the breeding season. A total of 50 sub-estrus buffaloes, identified through ultrasonography (USG) examination, were randomly allocated into three groups, viz.

View Article and Find Full Text PDF

The characterization of thin films containing nanopores with diameters exceeding 50 nm poses significant challenges, especially when deploying sorption-based techniques. Conventional volumetric physisorption or mercury intrusion methods have limited applicability in thin films due to constraints in sample preparation and nondestructive testing. In this context, ellipsometric porosimetry represents a viable alternative, leveraging its optical sensitivity to thin films.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!