Background: The guidelines to correct the mechanical axis in high tibial osteotomy (HTO) have changed recently, and some studies have suggested that the correction of the mechanical axis should be based on the severity of cartilage defect. The purpose of this study was (1) to evaluate the radiographic and clinical outcomes of HTO with concomitant cartilage procedures and (2) to compare our method with conventional method regarding the mechanical axis correction.
Methods: Sixty-six knees which underwent opening wedge HTO with cartilage procedures were evaluated retrospectively. The mean age was 56.0 ± 8.3 years, and the average follow-up period was 35.9 ± 22.0 months (range, 24-93 months) with a minimum follow-up of 2 years. All patients were divided into two groups regarding the method of mechanical axis correction; the postoperative mechanical axis was shifted to 50-55% of the tibial plateau width in group I (n = 46) and to 62-66% according to the conventional method in group II (n = 20). Concomitant cartilage procedures were performed, and each technique of those was determined according to the cartilage status.
Results: The functional scores and visual analog scale for pain in all patients showed a significant improvement at the final follow-up, but there was no significant difference between two groups. The postoperative mechanical axis was the valgus axis of 0.7° in group I with average mechanical axis deviation (MAD) of 51.7%, whereas the valgus axis of 4.2° in group II with average MAD of 64.0%. In patients who underwent second-look arthroscopy, the cartilaginous regeneration could be obtained by cartilage procedures.
Conclusion: In HTO with concomitant cartilage procedures, the method to correct postoperative mechanical axis to the neutral or valgus axis less than 3° could be an effective and safe method to obtain reliable clinical outcomes without complications. Therefore, our method can be used as a selective technique to prevent complications related to the postoperative valgus alignment in patients who are needed much correction angle due to the preoperative severe varus alignment.
Study Design: Retrospective comparative study, level III.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714077 | PMC |
http://dx.doi.org/10.1186/s13018-019-1333-4 | DOI Listing |
Biophys Physicobiol
September 2024
Department of Cell Biology, The University of Tokyo, Bunkyo-ku, Tokyo 113-0033, Japan.
Visceral organs in vertebrates are arranged with left-right asymmetry; for example, the heart is located on the left side of the body. Cilia at the node of mouse early embryos play an essential role in determining this left-right asymmetry. Using information from the anteroposterior axis, motile cilia at the central region of the node generate leftward nodal flow.
View Article and Find Full Text PDFAnal Chem
January 2025
Research Center of Analytical Instrumentation, School of Mechanical Engineering, Sichuan University, Chengdu 610065, People's Republic of China.
The development of an atmospheric pressure interface (API) with a high ion transfer efficiency and wide mass range is advantageous for the performance improvement of mass spectrometry (MS) instruments. In this work, a novel ion guide, namely, the double-helix electrode ion funnel (DHE-IF), has been developed to enhance the ion transmission over a wide mass range in the rough vacuum region. The DHE-IF consists of two funnel-shaped helix electrodes.
View Article and Find Full Text PDFLangmuir
January 2025
Department of Chemistry and Applied Chemistry, Saga University, 1 Honjo, Saga City, Saga 840-8502, Japan.
This study introduces a novel method for fabricating multicavity, honeycomb-shaped collagen aerogels characterized by continuous pores. We have taken a unique approach to lyophilizing collagen hydrogels, which are UV-irradiated collagen solutions gelatinized in a carbonate buffer solution. The focus of this study was to investigate the effect of UV irradiation times on collagen solutions on collagen hydrogels and aerogels.
View Article and Find Full Text PDFISA Trans
January 2025
Leuphana University of Lueneburg, Universitaetsallee 1, 21335 Lueneburg, Germany. Electronic address:
This paper addresses a non-interacting torque control strategy to decouple the d- and q-axis dynamics of a permanent magnet synchronous machine (PMSM). The maximum torque per ampere (MTPA) method is used to determine the reference currents for the desired torque. To realize the noninteracting control, knowledge concerning the inductances L and L of the electrical machine is necessary.
View Article and Find Full Text PDFAm J Orthod Dentofacial Orthop
January 2025
Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey. Electronic address:
Introduction: The objective of this study was to evaluate the effects of the miniplate application sites in the maxilla and the applied force vector changes during skeletally supported facemask application in adolescent patients with unilateral cleft lip and palate (UCLP) using finite element model (FEM) analysis.
Methods: A FEM was obtained from a cone-beam computed tomography image of a 12-year-old female patient with UCLP. Miniplates were placed on 3 different sites of the maxilla; 500 g of advancement force was applied bilaterally, parallel (0°), and downward (-30°) to the occlusal plane.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!